background image

14

USES

The appliance can be arranged only for filte-

ring performances. In its filtering version the 

air and fumes conveyed by the appliance are 

cleaned both by a grease filter and by an ac-

tive coal filter, and put again into circulation.

INSTALLATION

At tge beginning make sure that the packa-

ge  is  intact  and  all  the  parts  are  unbroken, 

otherwise  stop  the  installation  and  contact 

the  dealer. 

The  manufacturer  is  not  re-

sponsible for damages caused by material 

handling or product installation.

Before  installing  the  appliance  read  all 

these instructions carefully.

Take  the  wall  bracket  from  the  packaging 

and  install  it,  by  means  of  using the  provi-

ded screws and small blocks, as in figure 1. 

It  is  possible  to  use  the  same  bracket  as  a 

template and draw the drilling to be done in 

the wall. 

Warning:

 before fixing the bracket it is ne-

cessary to pay attention to the following: 

1 -The feeding cable must be inside the bra-

cket, as shown in fig. 2; 2 - The bracket must 

be installed with a perfect horizontal axis in 

regard to the floor, as in fig. 3; 3 - The wall 

on which the product is installed must be ro-

bust enough, considering that the product as 

a weight of approximately .... kilos. 

Take  the  ducting  product  from  the  packa-

ging. Protect the installation pipe with some 

paper sellotape, as shown in fig. 4. 

Insert  the  wall  plate,  as  shown  in  figure  5, 

paying attention not to damage the finishing 

of the pipe - protected with the paper sello-

tape, as described in the previous point. 

Fix the product to the wall bracket, previously 

installed, inserting the installation pipe in the 

specific socket of the bracket, see fig. 6. 

Clamp the product, using the provided screw, 

inserting  it  as  in  fig.  7.  Fix  it  all,  using  the 

provided M6 nut. 

In case the product proves to be not perfectly 

perpendicular to the floor plan, it is possible 

to do a further adjustment, securing the screw 

indicated in fig. 8, to move the lower part of 

the  product  away  from  the  wall  on  which  it 

is installed (fig. 9). While securing the screw 

(fig.  8),  push  the  lower  part  of  the  product 

from the bottom up to ease the adjustment. 

Proceed with the electrical connection of the 

product (fig. 16). 

Place the cover on the wall plate (fig. 10), then 

fix it with the two provided screws (fig. 11).

Summary of Contents for SLT105

Page 1: ...OR DE KLANT INFORMAZIONI TECNICHE TECHNICAL INFORMATION INFORMATION TECHNIQUES INFORMACIONES T CNICAS TECHNISCHE INFORMATIONEN TECHNISCHE INFORMATIES TYPE FSLA ISTRUZIONI PER INSTALLAZIONE USO E MANUT...

Page 2: ...2...

Page 3: ...rective 2012 19 EC on waste electrical and electronic equipment WEEE GB Le symbole sur le produit ou son emballage indique que ce produit ne peut tre trait comme d chet m nager Il doit plut t tre remi...

Page 4: ...EU Richtlinie 2012 19 EC ber Elektro und Elektronik Altger te WEEE D Het symbool op het product of op de verpakking wijst erop dat dit product niet als huishoudafval mag worden behandeld Het moet echt...

Page 5: ...INDICE Avvertenze Versioni d uso Installazione Funzionamento Manutenzione 5 IT...

Page 6: ...arbone ecc vengono usati contemporaneamente La cappa aspirante evacuando l aria po trebbe creare una pressione negativa nella stanza La pressione negativa del locale non deve superare i 0 04 mbar evit...

Page 7: ...to come da figura 3 3 La parete su cui viene installato il prodot to deve sufficientemente robusta considera re che il prodotto ha un peso di circa KG Prelevare il prodotto dall imballaggio pro teggen...

Page 8: ...configurazione di fabbrica prevede che tutti i sistemi cappa radiocomando ab biano lo stesso codice di trasmissione Nel caso siano installati due sistemi cappa ra diocomando nello stesso locale o nell...

Page 9: ...t passa automaticamente alla II velocit dopo 7 minuti Resta comunque possibile modificare le velocit in uso Il prodotto in modalit stand by ha un con sumo inferiore a 0 5W 9 Ripristino della configura...

Page 10: ...to immediatamente dietro al filtro antigrasso ed possibile rimuoverlo in maniera analoga La sostituzione del filtro al carbone avviene in rapporto all uso almeno una volta ogni sei mesi Per la pulizia...

Page 11: ...CONTENTS Warnings Uses Installation Working Maintenance 12 GB...

Page 12: ...lectrical connec tions on the appliance please make sure that them current tap is provided with earth connection and that voltage values correspond to those indicated on the label placed inside the ap...

Page 13: ...n regard to the floor as in fig 3 3 The wall on which the product is installed must be ro bust enough considering that the product as a weight of approximately kilos Take the ducting product from the...

Page 14: ...requires all cooker hoods radio control system to be pro vided with the same transmission code In the event two cooker hoods radio control system are installed in the same room or ne arby each system...

Page 15: ...atically switched to 2nd speed after 7 minutes operation Operation speeds can also be changed during operation The energy consumption of the appliance in stand by mode is lower than 0 5W 17 within 5 s...

Page 16: ...ilter and can be remo ved in the same way To replace the neon lamp or the related fe eder it is necessary to open the light panel as previously described see fig 13 then to remove the perimeter screws...

Page 17: ...47 1 4 5 6 2 3...

Page 18: ...48 12 7 11 10 8 9...

Page 19: ...49 14 15 16 13...

Page 20: ...50...

Page 21: ...51...

Page 22: ...90001050099 MG 10 16...

Reviews: