background image

16

WORKING

Remote control (Fig.12)

channel radio control for cooker hood remo-

te.

At  first  ignition,  keep  pressed  the  lighting 

button for 5 seconds.

RC001

R

ADIO

 C

ONTROL

Radio control used for the remote operation 

of ducted cooker hoods.

TECHNICAL DATA

- Alkaline battery powered: 12 V mod. 23 A

- Operating frequency: 433.92 Mhz

- Combinations: 32.768

- Max. consumption: 25 mA

- Operating temperature: -20 ÷ + 55 °C

- Dimensions: 120 x 45 x 15 mm.

OPERATING DESCRIPTION

The  transmitter  is  equipped  with  5  buttons 

for  cooker  hood  management,  as  specified 

below:

 

: Light ON/OFF command.

 

: Motor ON (speed level 1) / OFF command.

 

: Reduce speed.

 

: Increase speed.

 

: 10-minute timer.

The set suction speed is indicated by the LED 

in the suction perimeter channel.

To each color generated by the LED, it cor-

responds a specific speed, as shown below:

First speed WHITE

Second speed BLUE

Third speed DARK BLUE

Fourth speed RED

INITIAL OPERATING CONDITION

The manufacturer supplies the radio control 

unit ready to be used with codes preset in the 

Factory

OPERATION MODE 

Standard configuration:

Standard  configuration  requires  all  “cooker 

hoods  –  radio  control  -  system”  to  be  pro-

vided  with  the  same  transmission  code.  In 

the  event  two  cooker  hoods  –  radio  control 

system are installed in the same room or ne-

arby, each system may affect the operation of 

the another. Therefore, the code of one radio 

control system must be changed.

Generatiing a new transmiissiion code:

The  radio  control  system  is  provided  with 

preset  codes.  Should  new  codes  be  requi-

red, proceed as follows: Press simultaneously 

buttons:

for  two  seconds.  When  Leds  light  on,  press 

buttons: 

(within 5 seconds). Leds flashing 3 times in-

dicate

the procedure is completed.

WARNING! This  operation deletes  perma-

nently the preset codes.

Learniing the new transmiissiion code:

Once the transmission code is changed in the 

radio control unit, the electronic central unit 

of the cooker hood must be made to set the 

new code in the fol- lowing way:

Press the main power-off button of the hood 

and then restore power to the electronic con-

trol unit. Within the next 15 seconds, press 

the Liight Button        to synchronise the cen-

tral unit with the code.

Reset of the Factory confiiguratiion:

To  restore  the  Factory  configuration,  follow 

the  pro-  cedure  described  below:  press  si-

multaneously buttons:

for 2 seconds. When Leds light on, press but-

tons:

Summary of Contents for SLT105

Page 1: ...OR DE KLANT INFORMAZIONI TECNICHE TECHNICAL INFORMATION INFORMATION TECHNIQUES INFORMACIONES T CNICAS TECHNISCHE INFORMATIONEN TECHNISCHE INFORMATIES TYPE FSLA ISTRUZIONI PER INSTALLAZIONE USO E MANUT...

Page 2: ...2...

Page 3: ...rective 2012 19 EC on waste electrical and electronic equipment WEEE GB Le symbole sur le produit ou son emballage indique que ce produit ne peut tre trait comme d chet m nager Il doit plut t tre remi...

Page 4: ...EU Richtlinie 2012 19 EC ber Elektro und Elektronik Altger te WEEE D Het symbool op het product of op de verpakking wijst erop dat dit product niet als huishoudafval mag worden behandeld Het moet echt...

Page 5: ...INDICE Avvertenze Versioni d uso Installazione Funzionamento Manutenzione 5 IT...

Page 6: ...arbone ecc vengono usati contemporaneamente La cappa aspirante evacuando l aria po trebbe creare una pressione negativa nella stanza La pressione negativa del locale non deve superare i 0 04 mbar evit...

Page 7: ...to come da figura 3 3 La parete su cui viene installato il prodot to deve sufficientemente robusta considera re che il prodotto ha un peso di circa KG Prelevare il prodotto dall imballaggio pro teggen...

Page 8: ...configurazione di fabbrica prevede che tutti i sistemi cappa radiocomando ab biano lo stesso codice di trasmissione Nel caso siano installati due sistemi cappa ra diocomando nello stesso locale o nell...

Page 9: ...t passa automaticamente alla II velocit dopo 7 minuti Resta comunque possibile modificare le velocit in uso Il prodotto in modalit stand by ha un con sumo inferiore a 0 5W 9 Ripristino della configura...

Page 10: ...to immediatamente dietro al filtro antigrasso ed possibile rimuoverlo in maniera analoga La sostituzione del filtro al carbone avviene in rapporto all uso almeno una volta ogni sei mesi Per la pulizia...

Page 11: ...CONTENTS Warnings Uses Installation Working Maintenance 12 GB...

Page 12: ...lectrical connec tions on the appliance please make sure that them current tap is provided with earth connection and that voltage values correspond to those indicated on the label placed inside the ap...

Page 13: ...n regard to the floor as in fig 3 3 The wall on which the product is installed must be ro bust enough considering that the product as a weight of approximately kilos Take the ducting product from the...

Page 14: ...requires all cooker hoods radio control system to be pro vided with the same transmission code In the event two cooker hoods radio control system are installed in the same room or ne arby each system...

Page 15: ...atically switched to 2nd speed after 7 minutes operation Operation speeds can also be changed during operation The energy consumption of the appliance in stand by mode is lower than 0 5W 17 within 5 s...

Page 16: ...ilter and can be remo ved in the same way To replace the neon lamp or the related fe eder it is necessary to open the light panel as previously described see fig 13 then to remove the perimeter screws...

Page 17: ...47 1 4 5 6 2 3...

Page 18: ...48 12 7 11 10 8 9...

Page 19: ...49 14 15 16 13...

Page 20: ...50...

Page 21: ...51...

Page 22: ...90001050099 MG 10 16...

Reviews: