background image

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

VENTING REQUIREMENTS

RH2330XJ
RH2336XJ

RH2630XJ

Electrical:

120-volt, 60-Hz, AC-only, 15-amp. electrical

supply. Use copper wire only. A time-delay fuse or circuit
breaker and separate circuit is recommended.

®

Range Hood – 24" (58cm), 30" (76.2 cm), 36" (91.4 cm)

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. W10112419

02-13-08

23-7/8" (60.6 cm) – 24" (61.0 cm) model
29-7/8" (75.9 cm) – 30" (76.2 cm) model
35-7/8" (91.1 cm) – 36" (91.4 cm) model

7-1/2" 

(19.1 cm)

2" 

(5.1 cm)

1-1/2" 

(3.8 cm)

1" 

(2.5 cm)

1-1/2" 

(3.8 cm)

6" 

(15.2 cm)

9" 

(22.9 cm)

12" 

(30.5 cm)

3/4" 

(1.9 cm)

3/8" 

(9.5 mm)

17-1/2" 

(44.5 cm)

3-1/4" x 10" (8.3 x 25.4 cm) vent system

3-1/4" x 10" (8.3 x 25.4 cm) vent system

Maximum length

=  35 ft.

(10.7 m)

1 - 90° elbow

=   5 ft.

(1.5 m)

8 ft. (2.4 m) straight

=   8 ft.

(2.4 m)

1 - wall cap

=   0 ft.

(0 m)

Length of 3-1/4" x 
10" (8.3 x 25.4 cm) system

= 13 ft.

(3.9 m)

Note: Flexible vent is not recommended

3-1/4" x 10" 
(8.3 x 25.4 cm)
90° elbow = 
5 ft. (1.5 m)

3-1/4" x 10" 
(8.3 x 25.4 cm)
flat elbow = 
12 ft. (3.7 m)

3-1/4" x 10" 
(8.3 x 25.4 cm)
wall cap = 

0 ft. (0 m)

2 ft.
(0.6 m)

6 ft. ( 1.8 m)

wall cap

3-1/4" x 10" 
(8.3 x 25.4 cm)
elbow

Maximum length

= 35 ft.

(10.7 m)

1 - 90° elbows

= 5 ft.

(1.5 m)

8 ft. (2.4 m) straight

= 8 ft.

(2.4 m)

1 - wall cap

= 0 ft.

(0 m)

Length of 7" 
(17.8 cm) system

= 13 ft.

(3.9 m)

Note: Flexible vent is not recommended

6" (15.2 cm) vent system

3-1/4" x 10" 
(8.3 x 25.4 cm) to
6" (15.2 cm) = 
4.5 ft. (1.4 m)

90° elbow =
5 ft. (1.5 m)

45° elbow =
2.5 ft. (0.8 m)

3-1/4" x 10" 
(8.3 x 25.4 cm) 
to 6" (15.2 cm) 
90° elbow = 
5 ft. (1.5 m)

6" (15.2 cm)
wall cap = 
0 ft. (0 m)

elbow

wall
cap

6 ft. (1.8 m)

2 ft.

(0.6 m)

6" (15.2 cm) vent system

36" (91.4 cm)
base cabinet
height

24" (61.0 cm ) min.

30" (76.2 cm)

suggested max.

bottom of hood to

cooking surface

13" (33 cm)

cabinet depth

18" (45.7 cm) min.

24" (61 cm)

suggested max.

bottom of cabinet

to cooking

surface

24" (61.0 cm) or
30" (76.2 cm) or

36" (91.4 cm)

min. cabinet 

opening width

CABINET OPENING DIMENSIONS

Roof Venting

 

Wall Venting

A. 6" (15.2 cm) round vent or a 

(8.3 x 25.4 cm) vent through roof 

B. Round vent: use 6" (15.2 cm) round  

damper (purchased separately)

C. 18" (45.7 cm) to 24" (61.0 cm) 

above cooking surface

D. Roof cap

B. 3

¹⁄₄

" x 10" (8.3 x 25.4 cm) vent 

through the wall

C. 18" (45.7 cm) to 24" (61.0 cm)  

above cooking surface

D. Wall cap

A

B

D

C

A

B

C

D

3

¹⁄₄

" x 10"

A. 6" (15.2 cm) round vent or a 

(8.3 x 25.4 cm) vent through wall

3

¹⁄₄

Reviews: