Operating and assembly instructions

AH 590-120
AH 592-120

Freely Suspended Insular Hood

 

Summary of Contents for AH 590-120

Page 1: ...Operating and assembly instructions AH 590 120 AH 592 120 Freely Suspended Insular Hood ...

Page 2: ...2 120 Preface 1 Important notes Page 3 4 1 1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 ...

Page 3: ... important notes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va lue of your appliance You will find notes on Page 4 that you ought to observe before operating the appliance for the first time The chapters entitled Features and Operation will tell you ...

Page 4: ...s poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the corresponding fuse If the mains plug is not accessible the appliance must be disconnected from the power mains by means of the domestic installation fuse Repairs must be carried out by authorised specialists thus ensuring electrical safety No warr...

Page 5: ...to the fact that there are accessories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter entitled Cleaning and care Before operating the appliance for the first time check that the mains connection is in proper working order 1 3 About use The appliance is intended solely for use in the household and m...

Page 6: ...heights of 2 64 2 89 m LK 590 030 for ceiling heights of 2 89 3 14 m Aluminium design ventilation duct LK 590 011 for ceiling heights of 2 39 2 64 m LK 590 021 for ceiling heights of 2 64 2 89 m LK 590 031 for ceiling heights of 2 89 3 14 m Fig 2 1 2 3 4 Fig 3 Motor off Extraction level 1 Extraction level 2 Extraction level 3 Extraction level intensive Delayed shut off Lighting Grease filter satur...

Page 7: ...ation by pressing the key see Fig 4 When you briefly press the key the lighting is in creased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan levels Three fan speeds and one intensive speed are available see Fig 5 You set the fan level required for each respective cooking situation by pressing the function selector keys 1 2 3 or Int Fig 5 Fig 4...

Page 8: ...ress the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like to end the intensive level before the five minutes have elapsed press the 0 key Motor off or select a different level see Fig 8 It is possible to switch off the extraction function at any time by pres...

Page 9: ...r all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour You can activate this function by simultaneously pressing the 0 key and depending on the required extraction capacity the 1 2 or 3 key see Fig 11 ...

Page 10: ...s out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported vertically to allow food or rinsing residues to drain off If possible the inner parts of the housing should be wiped out in hot rinsing water when replacing the filters Caution when cleaning the inside o...

Page 11: ...ingly with a blunt object e g handle of a wooden spoon to detach them with greater ease The remaining glass plates can then be lifted from above If they are extremely soiled the glass plates can be cleaned in a dishwasher at a maximum temperature of 55 C Note when putting the glass plates back in place make sure that you do not scratch the chimney Replace the glass plates with the printed side fac...

Page 12: ...nce Improper tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortly after use Risk of burns Detach the ring from the lamp cover Note make sure that the glass will not fall out Fig 16 Pull out the lamp Fig 17 Defective lamps must only be replaced by lamps of the sa...

Page 13: ...op to the bottom edge of the hood is for electrical appliances 600 mm and for gas appliances 700 mm The extractor hood was conceived for the exhaust air mode The exhaust air can be routed into a se parate exhaust air shaft or directly into the open through the outside wall It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is link...

Page 14: ...condensate or rain water from an uncovered exhaust air shaft our condensate separator RV 060 150 must be installed in the exhaust air line The condensate separator must still be accessible after installation The duct units listed below are available depen ding on the height of the ceiling Stainless steel design ventilation duct LK 590 010 for ceiling heights of 2 39 2 64 m LK 590 020 for ceiling h...

Page 15: ...x 15 minutes if the hood is running on a minimum of level 2 Otherwise there is a risk of burns when touching the exterior of the ex tractor hood The following note applies to extractor hood AH 592 120 only this model does not have an integrated fan The extractor hood can only be used in exhaust air mode The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft ...

Page 16: ... FRONT must be on the same side as the control panel Fig 20 Ventilation ducts LK 590 020 030 021 031 only the enclosed extension module should be mounted on top of the support frame Follow the above instructions for mounting the support frame and hood 346 200 Fig 19 Fig 20 Note the extractor hood is to be installed to a kitchen ceiling or suspended ceiling Ensure that the ceiling is capable of pro...

Page 17: ...l ventilation ducts only LK 590 010 020 030 pull the protective film off the metal surface 8 Place both ventilation ducts over the support frame Take care not to scratch the sensitive duct surface 9 Attach the electrical plug to the support frame with sticky tape so that it can be easily reached later 10 Hang the hood and the support frame with the two key holes to the two screws in the ceiling Fi...

Page 18: ... on the support frame Fig 24 Note avoid scratches when pulling the ele ments apart by placing the assembly template for example over the top edge of the bottom duct to protect it 15 Replace the glass plates with the printed side facing down Position the glass plates at the chimney side first Note when putting the glass plates in place make sure that you do not scratch the chimney 16 Check the appl...