All-Fuel Chimney System

Installation Instructions

Toll-Free

 1-866-667-8454 

NorthlineExpress.com

www.NorthlineExpress.com

Summary of Contents for DuraVent DuraPlus 7DP-CS11

Page 1: ...DuraPlus All Fuel Chimney System Installation Instructions Toll Free 1 866 667 8454 NorthlineExpress com www NorthlineExpress com...

Page 2: ...an effect on your homeowner s insurance and UL listing status Keep these instructions for future reference This booklet also contains instructions for installing a venting system within an existing m...

Page 3: ...et Chart 13 Extended Roof Bracket Installation 14 Roof Supported Installations 15 Tee Supported Installations 16 Masonry Fireplace Installations 18 Zero Clearance Fireplace Installations 21 Connection...

Page 4: ...ire Official regarding permits restrictions and installation inspections in your area DuraPlus APPLICATIONS Use DuraPlus with wood stoves fireplaces furnaces boilers water heaters stoves ranges or oth...

Page 5: ...uraPlus may be installed up to 35 feet high If a chimney is installed higher than 35 feet a supporting Elbow Strap must be placed every 8 feet If the chimney extends more than 4 feet above the roof an...

Page 6: ...appliances installed with DuraPlus chimney systems Choice Choose a stove that is listed by a recognized testing laboratory is appropriate for your needs and is not larger than required Installation On...

Page 7: ...ceiling Refer to Table 2 for specific framing and clearance dimensions Mark appropriate cutting lines around the center point Cut a square hole in the ceiling for a Square Support Box or a round hole...

Page 8: ...d ceilings install Firestop Radiation Shields Where the chimney passes through an attic Firestop Radiation Shields and Insulation Shields must be installed 4 Frame Openings Frame openings in each ceil...

Page 9: ...ney passes through Close Clearance Shields When using Close Clearance Shields Ventilated Flashing must be installed Refer to Figure 10 which pictures both Ventilated and Non ventilated Flashing 6 Inst...

Page 10: ...ion Shield Install the Attic Insulation Shield where the chimney passes into an attic It s purpose is to prevent debris and insulation from getting too close to the chimney Figure 12 An installed Atti...

Page 11: ...ion up through the Flashing Always insure the chimney remains vertical and that at least a 2 inch clearance to combustible materials is maintained all around Install the upper edge of the Flashing und...

Page 12: ...s Enclose chimneys where they pass through occupied spaces including closets Always maintain at least a 2 inch clearance between the chimney and any combustible surface Interior enclosures may be cons...

Page 13: ...f the top Elbow then tighten the nut and bolt until the clamp is firm Wrap the Elbow Strap end over an adjacent joist or rafter and secure it with at least two 8 penny nails Do not add more Chimney Se...

Page 14: ...ing waterproof sealant 3 Attach Conduit Flatten 1 inch and drill a 1 4 inch hole at each end of both pieces of conduit Bolt each conduit to the Pipe Band and Roof Brackets with the nuts and bolts prov...

Page 15: ...gs Cut a roof opening directly above the appliances flue outlet collar just as in a Ceiling Supported Installation Steps 1 thru 5 If a separate ceiling and roof exists as shown in Figure 20 Low Attic...

Page 16: ...ruction prior to sheetrock or other covering of the wall studs is applied frame a square opening between the studs as specified in Table 2 Figure 25 Should it be necessary to go through concrete mason...

Page 17: ...tside view from outside Figure 27 note if system exits thru wall into garage an enclosure isrequired ventilated flashing must be used 2 inches minimum enclosure GARAGE 2 inches minimum access door for...

Page 18: ...alling the chase cover requires some special considerations The chase must be ventilated at the top and a 1 2 inch air gap must be established between the cover and the framed chase top In addition a...

Page 19: ...or chimney height requirements Always maintain at least 2 inches of clearance to combustible materials and enclose the chimney where it passes through occupied areas Use a Wall Strap for every four fe...

Page 20: ...20 Table 4 Toll Free 1 866 667 8454 NorthlineExpress com www NorthlineExpress com...

Page 21: ...the ceiling support or wall thimble Align the tabs on the slip connector with the notches in the face of the support or wall thimble push the connector in and twist to lock it in Further instructions...

Page 22: ...attach the cap s support legs to the cap base The Tee Cleanout Cap can be removed once the screws are unscrewed Remember to replace the cap when you are finished cleaning the chimney 5 Coal To reduce...

Page 23: ...23...

Page 24: ...r and Components warranty is further subject to compliance with the following requirements throughout the warranty period The chimney must have a chimney cap and chemical chimney cleaners must not be...