Switch on the unit and start space heater by adjusting the function switch (No.2 Fig.1) to the
position reqired: A or B or C (A, B or C Fig.4.) The space heater is equipped with an adjustable
thermostat.
The temperature required is set by means of the adjustment button (No.1 Fig.1), after which the
heater runs automatically. Before switching off the heater it is recommended to switch the heating
elements off by change over to
Fan mode
(pos. C Fig.4) for a couple of minutes in order to cool
down the unit before switching over to
Off
(pos.D Fig.4) or before interrupting the mains supply.
If, however, the heating is interrupted by means of the function switch heater automatically turns
to cooling option up to 5 minutes.
Working with the hot air distributing hose
Device is adapted to work with hot air distributing hose Φ 305mm. Distributing hose length
maximum 15m, must be heat resistant up to 100
0
C. Hose have to be connected correctly to the hot
air outlet. Make sure hose is not folded during operation.
Fig. 5 Device description:
1. handle
2. air outlet
3. motor with fan
4. function switch
5. thermostat knob
6. casing
7. external thermostat socket
8. plug with socket
9. wheel