GTJZ0408SE&0608SE&0408ME&0608ME Operation Manual
ELECTRICAL SHOCK HAZARDS
•
Always maintain a safe distance
from power lines and electrical
equipment in accordance with ap-
plicable government regulations
and see
.
•
Consider platform movement,
wire swinging or drooping, be-
ware of strong winds or gusts,
and do not operate the machine
when there is lightning or heavy
rain.
•
If the machine comes into contact
with live wires, keep away from
the machine. Personnel on the
ground or on the platform must
not touch or operate the machine
until the power is switched off.
•
Do not use the machine as a
ground wire during welding and
polishing operations.
Table 3-1
Voltage
(Phase to Phase, kV)
Minimum Safe Distance
(m/ft)
0-50
3.05 (10)
50-200
4.60 (15)
200-350
6.10 (20)
350 -500
7.62 (25)
500 -750
10.67 (35)
750 -1000
13.725 (45)
TIPPING HAZARDS AND
RATED LOAD
Maximum rated load bearing capacity of the platform:
Table 3-2
GTJZ0408SE&0608SE
Retracting
280 kg(617 lb)
Extending: Stationary only
160 kg(352 lb)
Extending: Extension only
120 kg(265 lb)
GTJZ0408ME&0608ME
Retracting
230 kg(507 lb)
Extending: Stationary only
110 kg(242 lb)
Extending: Extension only
120 kg(265 lb)