heater.

 

 

 

 

MAINTENANCE 

 

Maintenance should only be carried out by a qualified electrician. 

 

During operation it is necessary to periodically (once a year) check the electrical cable contacts and terminal connectors for 

proper tightening. 

 

If the heater gets dirty, wipe off the dust with a damp cloth, the parts radiants must be cleaned cold with a soft damp cloth. 

WARNING!   

 

Never immerse the appliance in water! Danger of death! 

 

TROUBLESHOOTING 

The possible malfunctions are shown in the table below.   

SYMPTOMS

 

CAUSE

 

Does not heat up / No function indicators

 

Check that the power supply is connected and switched on

 

The heater smells when it is used for the 

first time.

 

This is caused by the oil or dust left over from the production process 

and will stop after a short period of time.

 

Weak odour for short periods after the 

heater is switched on

 

This is normal and should stop after a short time.

 

The heater stinks when turned on after 

periods of inactivity

 

Formation of debris and dust on the heater, Turn off the heater and let 

it cool and then clean it

 

Tinkle noises when the heater is on and 

after being switched off

 

These are noises of expansion and contraction of the metal components 

of the heaters and is normal

 

Poor heating performance

 

Exposure to extreme environmental conditions such as strong winds / 

excessively cold temperatures can lower the heating performance of an 

outdoor installation. 

The unit is not installed in the correct position, perhaps too high or the 

heater is too small for the recommended area.

 

 

 

When to contact the service department or authorized seller 

There are no user-serviceable parts in this unit, but only an authorized person can service or maintain this unit by a qualified 

electrician. 

SYMPTOMS

 

CAUSE

 

There is a burning smell and strange 

sounds (different from normal expansion 

and contraction noises) coming from the 

unit.

 

Turn off the heater and contact the seller.

 

Summary of Contents for C1500B

Page 1: ...0B CH15A7R CALORE BIANCO 1800 C1800B CH18A7R CALORE BIANCO 2400 C2400B CH24A7R CALORE BIANCO 3200 C3200B CH32A7R CALORE NERO 1500 C1500N CH15A7R BLACK CALORE NERO 1800 C1800N CH18A7R BLACK CALORE NERO...

Page 2: ...The photo is only indicative the actual may appear slightly different in colour...

Page 3: ...s serious burns may occur The appliance may take up to 1 hour to cool down after switching off Do not place any clothes towels or similar on top of the heater to dry Risk of overheating and fire Do no...

Page 4: ...the dangers Children must not play with the appliance Cleaning and maintenance of the appliance must not be carried out by children without supervision The appliance is intended exclusively for the p...

Page 5: ...CALORE BIANCO NERO 2400 CH24A7R CALORE BIANCO NERO 3200 CH32A7R Voltage 230 240V 50Hz 230 240V 50Hz 230 240V 50Hz 230 240V 50Hz Rated power W 1500 1800 2400 3200 Ideal wall mounting height M 1 8 2 1...

Page 6: ...heating or cooling period This is a normal operating noise NOTE The discoloration of the paint on the wall of the heater body direct to the ceiling during operation is not a defect The colour change...

Page 7: ...hing figure 4 4 When the appliance is in heating or standby mode point the remote control directly at the receiver and press the low button the appliance will beep and start heating in lower power mod...

Page 8: ...and then the 2h button to activate the 3 hour timer figure 11 Press the 1h 2h 4h and 6h button in order to activate a timer of maximum 13 hours figure 12 INSTALLATION Please read the manual carefully...

Page 9: ...rface must always be positioned so that the heat is directed downwards or outwards Authorizations Minimum distances when mounting the heater on A VERTICAL WALL Minimum distances for mounting the heate...

Page 10: ...height angle options 4 The correct installation process as shown in the diagram above selects the position of the heater on the ceiling by positioning the structural pivot or beams to ensure a safe fi...

Page 11: ...the 230 240V 50Hz single phase mains power supply with grounding Before connection make sure that the specifications of the power grid at the connection point meet the single phase 230 240V 50Hz volta...

Page 12: ...l and should stop after a short time The heater stinks when turned on after periods of inactivity Formation of debris and dust on the heater Turn off the heater and let it cool and then clean it Tinkl...

Page 13: ...void possible damage to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please...

Reviews: