7. Hang the heater from the brackets and secure it firmly in place with the mounting bracket locking plates by tightening the
bolts.
NOTE:
Depending on the material and design of the structural elements of the ceiling or wall, the heater must be fixed with the
correct fasteners. The weight of the heater is up to 9.5 kg, the installation site must be able to support 5 times the weight
of the heater.
It is the installer's responsibility to choose the correct wall or ceiling fixing.
Mains connection
•
The heater is designed for connection to the 230-240V~ 50Hz single-phase mains power supply with grounding
•
Before connection, make sure that the specifications of the power grid at the connection point meet the single-phase 230-
240V~ 50Hz voltage.
•
The mains power supply must be equipped with an automatic circuit breaker with a nominal current of not less than 16A.
•
It is strongly recommended to use a switch with an earth circuit.
•
The heater must not be placed immediately below the socket. The socket must not be positioned behind the heater. The
power outlet must be outside the physical footprint of the heater to minimize heat build-up behind the heater.
•
If the heater is to be mounted on a slope (e.g. vaulted ceiling), make sure that the supply point is at the lowest point of the