4.3.10 Sensor setting (Fig.7)
Press the “
FAN
+
SWING
” button
for 10 seconds in the “
OFF
”status to
enter the senor setting menu. A code
will be displayed on the “
ROOM TEMP
.”
“
01
”means the indoor unit sensor, and
“
02
”means the wired controller senor,
press “▲”and “▼”to chose the senor. If
there is no operation in 20 seconds, the
system will exit this menu and the present
setting will be saved, or else press “
ON/
OFF
”
button to save and exit.
MO DE
ON /OFF
TIMER
SWING
FAN
Fiig.8
4.3.11 System parameters display
(Fig.8)
Press “
FAN
+
SWING
” for 10 seconds
while the system is
ON
to enter the
system parameters displa interface.
The temperature of the water valve,
pump and surface cooler in the system.
The temperature of the surface cooler
is display at “
TIMER
”the two position
value display at “
TEMP.SET
” means
“
Valve 1
” and “
Valve 2
”, the status of the
pump displays at “
ROOM TEMP.
”and “
1
”
means
ON
while “
2
” means
OFF
. Press
ON/OFF
button to exit or else the system
will automatically exit after 30 minutes.