4. Connect the blue wire among power connect wires onto terminal N(1) on line bank, black

wire onto terminal 2 and yellow-green one (earth wire) onto terminal     (as shown in fig.4).

5. Put the section of power connect wire with sleeve into clamp groove, cover wire cover plate,

screw on fixing bolts to tighten the wires.

7. Cover panel.

6. To cooling and heating unit, signal control wire connect with indoor unit via connector, and

has the wire tightened by clamp at bottom of the unit's body (as shown in fig. 5).

Wire cover plate

Power

Connect 

Fig. 3

Linebank

Power connect wire

Fig. 4

☆ 

Electric Wiring

1. Open panel upwardly (as shown in fig. 2):
2. Take off fixing bolts of wire cover plate to take off the plate (as shown in fig.3).
3. Make power connect wire goes through the single wire hole at rear side of indoor unit and

Fig. 2

Note:

If the connecting wire was not long enough, please contact the appointed service shop to
 match another special wire that was long enough. Don't prolong wires.

 

Don't connect wire in wrong for it would cause malfunction on some components. 

 

Tighten bolts to prevent loosen of them.

 

After tighten bolts, pull wires slightly to see if they can be moved.

 

Electric shock may occur when earth wire is connected wrongly. 

 

Wire cover plate should be fixed well and tighten connecting wires. If the plate is 

not installed well, dust and moisture may get in or cause fire or electric shock for 

Signal control wire (only for cooling and heating unit)

Clamp

Fig. 5

pull it in front side.

wire

Blue

Black

Yellow-green

terminals were affected by outside force directly.

16

Summary of Contents for ASH-09AQ

Page 1: ...USER S MANUAL ASH 09AQ ASH 13AQ ASH 18AQ QUEEN SERIES ...

Page 2: ......

Page 3: ...th wet hand for electric shock may Don t insert finger or stick like thing into air outlet vent of indoor and outdoor unit Don t let cooled air blows body directly for too long and don t set indoor temp too low If abnormal phenomenon occurs like burning odor etc cut off power supply first then contact our service center If abnormal continues the unit may be damaged and cause Don t repair the unit ...

Page 4: ... heat of wire Don t let the unit blows to CO toxicosis may occur for heater or cooker directly Or imcomplete burning Chemical sprayer must be placed 1m or more away from both indoor and outdoor unit damaged without repair unit Note if install chassis is damaged If the chassis is may fall down and cause or things may fall down and Don t stand or put things on the outdoor unit For people cause injur...

Page 5: ...reless remote control Filter Guide louver Air in Air out Air in Air out High Medium Low Displayer All on in Auto Swing Sleep Dry Fan Window Receive Air purifying Air outlet grill Unit Drainage hose Outdoor Static dust catcher Connecting pipe and connecting wire Indoor Unit 3 functionless for this model ...

Page 6: ...etween 16 30 Under mode is between 16 30 Under mode 16 30 Every press of set temp lower 1 Temp Temperature button When transmitting and Every press of the button fan speed Fan Fan speed cannot be changed when Drying changes by following order PCB receives it as High speed Note Low is displayed as and Medium as High displayed as and Fan button Swing Auto Swing by 7 swing states below Stop Left and ...

Page 7: ...time rapidly The set ranges from 0 5 24 hours repress the button to confirm the time and transmit and Timer Off On sign stop blinking If the sign is blinking but no Timer Button is not repressed former set state would be resumed automatically after 10s When unit is on press this button can set auto off time and auto on time can be set when unit is off When Timer is set Timer control are not availa...

Page 8: ...r all indicator signs off automatically except power indicator sign then only power indicator 2 Press ON OFF on wireless remote control power indicator light off and present set running mode set temperature and fan speed etc are displayed at the same time unit begins running Note After 3 Press MODE to select proper running mode 4 Press SWING to select swing mode or fix the air supply in a certain ...

Page 9: ...is running When unit is running press the Swing on wireless remote Align proper airflow and direction control for left and right swing can align airflow horizontal direction press Swing for upper and lower swing can align Don t let the unit blow against pat and plant directly for it is not good for them The allowed voltage flucture of this unit is 230 10 V The strong shocking of compressor caused ...

Page 10: ...id rotating shaft in groove cover the panel cover according to arrow direction and Clean air filter Once about 3 months If the usage environment of the unit has lots of duct the cleaning of air filter should 1 Take off air filter Pull out the panel to an angle at both grooves on panel forcibly at the same time then pull the air filter downward to take it off As shown in right Clean it by soft brus...

Page 11: ...pply of the unit 3 Clear dust and things on outdoor unit 4 If outdoor unit rusts paint oil paint on rust to prevent spreading 2 Clean air filter Adopt ductcollector or water to clean filter If the filter is too dirty like oil spot clean it by warm water lower than 45 melted with neutral cleaning fluid Note Don t wash it by hot water whose temp is higher than 45 to prevent fade or deformation Don t...

Page 12: ...r of furniture and cigarette that sucked in the unit when it was working and now be blown out The unit cannot be restarted immediately after Once the unit be restarted immediately after turned off overload protect switch would make it run after Troubleshooting Warning Please don t repair the unit by yourself for incorrect repair would cause electric shock or fire please contact our service center ...

Page 13: ...f outdoor unit blocked Is there too much dust on air filter Are windows and doors closed Is airflow set to Low Is there any heat source in room when cooling is When unit is interfered by abnormal interference or too frequent of change function wireless remote control would not control occationally Plug out power Is the control in receive area Or is there onstruction Check if voltage of batteries i...

Page 14: ...en out easily 8 Ensure the installation of indoor unit fits requirements in Install Dimension Diagram Outdoor unit 1 Place where noise and airflow from the unit would not disturb neighbors 2 Place where there is well ventilation for outdoor unit 3 Obstructions are not allowed to exist around intake or outlet vent of outdoor unit 4 Place where can stand weight and shake of outdoor unit and ensure s...

Page 15: ...do conduct reliable earth connection 2 The yellow green wire in the unit is earth wire don t use it for other purpose and don t cut it Don t fix it by self tapping screw or electric shock may occur 3 Earth resistance should fits requirements of National Criteria GB17790 4 User s power must offer reliable earth terminal Please don t connect earth wire Water pipe Gas pipe Drainage pipe Places where ...

Page 16: ...e unit that was not installed by our service center would be hard to deal with in time for inconvenient It is better to be guided by professional personnel when moving the unit to other place Distance to floor Exhaust side Distance to ceiling Distance to wall Distance to wall Air in side Exhaust side Distance to cover Distance to wall Distance to wall or more 15cm or more 15cm or more or more or m...

Page 17: ...ainage hose must be placed at a downward slant for smooth drainage end by water 3 The indoor part of prolonged hose should be wrapped Wrenched Bent Don t flood it Install Connect Pipe 1 Connect the connect pipe with 2 leading pipes of indoor unit then tighten joint nuts on connect pipe 2 Tighten nuts on connect pipe forcibly and then tighten it by spanner Note Too great of torque would damage nuts...

Page 18: ...off the plate as shown in fig 3 3 Make power connect wire goes through the single wire hole at rear side of indoor unit and Fig 2 Note If the connecting wire was not long enough please contact the appointed service shop to match another special wire that was long enough Don t prolong wires Don t connect wire in wrong for it would cause malfunction on some components Tighten bolts to prevent loosen...

Page 19: ...e Wire Liquid side Heat insulator Heat insulator Drainage hose Wrap by strap Tailing 1 Tailing 3 Tailing 2 Fixing hook Install Install plate Right Rear right Left Rear left Fig 6 Fig 7 Fig 8 Install Indoor Unit 1 Align the flare of connect pipe to the joint flare of corresponding valve 2 Tighten nuts on connect pipe and then tighten it by spanner 1 Take off handle at right side of outdoor unit 2 T...

Page 20: ...s valve completely 8 Tighten the valve caps and test leakage at all joints of the pipe both indoor and outdoor unit with liquid soap or leakage detector 9 If it is possible exhaust air in unit by vacuum pump on gas core fig 10 Drainage of Condensate of Outdoor Unit unit and defrost water when defrosting could be drained to proper place by drainage hose Install method Insert the outdoor drainage jo...

Page 21: ...ffect Repress ON OFF button to stop the operation b Press ON OFF button when unit is on to stop the unit from operating Check after Installation Items to be checked Is installation firm Possible malfunction Unit may drop shake or emit noise Is leakage detect done It may lead insufficient of refrigerate capacity Is heat insulation sufficient Condensation or drop may occur Is drainage smooth Condens...

Page 22: ......

Page 23: ...g Select of Install Location Wire Allocation and Earth Requirement Install Dimension Diagram Install Indoor Unit Install Outdoor Unit Trial Run and Check Item after Installation Thank you for choosing SINCLAIR Air conditioner For correct use please keep this owner s manual carefully for consultation CONTENT Maintenance Install Service Instruction of Health Function ...

Page 24: ...ANT CHARGE Pursuant to Regulation EC 842 2006 on certain fluorinated greenhouse gases in case of extra refrigerant charge it is compulsory to Fill in the label accompanying the unit inserting the factory quantity of refrigerant charge see the technical label the extra refrigerant charge and the total charge Apply the label next to the technical label applied on the unit For the split type air cond...

Page 25: ......

Reviews: