4. Connect the blue wire among power connect wires onto terminal N(1) on line bank, black
wire onto terminal 2 and yellow-green one (earth wire) onto terminal (as shown in fig.4).
5. Put the section of power connect wire with sleeve into clamp groove, cover wire cover plate,
screw on fixing bolts to tighten the wires.
7. Cover panel.
6. To cooling and heating unit, signal control wire connect with indoor unit via connector, and
has the wire tightened by clamp at bottom of the unit's body (as shown in fig. 5).
Wire cover plate
Power
Connect
Fig. 3
Linebank
Power connect wire
Fig. 4
☆
Electric Wiring
1. Open panel upwardly (as shown in fig. 2):
2. Take off fixing bolts of wire cover plate to take off the plate (as shown in fig.3).
3. Make power connect wire goes through the single wire hole at rear side of indoor unit and
Fig. 2
Note:
If the connecting wire was not long enough, please contact the appointed service shop to
match another special wire that was long enough. Don't prolong wires.
●
Don't connect wire in wrong for it would cause malfunction on some components.
●
Tighten bolts to prevent loosen of them.
●
After tighten bolts, pull wires slightly to see if they can be moved.
●
Electric shock may occur when earth wire is connected wrongly.
●
Wire cover plate should be fixed well and tighten connecting wires. If the plate is
not installed well, dust and moisture may get in or cause fire or electric shock for
Signal control wire (only for cooling and heating unit)
Clamp
Fig. 5
pull it in front side.
wire
Blue
Black
Yellow-green
terminals were affected by outside force directly.
-