![Sinclair ASH-09AIM PT Service Manual Download Page 61](http://html.mh-extra.com/html/sinclair/ash-09aim-pt/ash-09aim-pt_service-manual_1280139061.webp)
56
Installation and Maintenance
Service Manual
1
2
1
2
pipe clamp
auxiliary piping
7. Remove electric box
Pull out the indoor temperature sensor.
Remove screws connecting electric box and bottom
case, loosen clasps, remove screws connecting
earthing wire and evaporator, and then remove the
electric box.
8. Remove evaporator
Turn over bottom case, remove screws connecting pipe
clamp and bottom case, loosen clasps between
connecting pipe clamp and bottom case, and then remove
the connecting pipe clamp.
Remove screws connecting evaporator and motor
press plate and bottom case, loosen clasps fixing
evaporator and bottom case, adjust the pipeline and
then remove the evaporator.
indoor temperature sensor
electric box cover
electric box
evaporator