29
Installation and Maintenance
Service Manual
(1) Take suf“ cient protective measures when installing the
outdoor unit.
(2) Make sure the support can withstand at least four times the
unit weight.
(3) The outdoor unit should be installed at least 3cm above the
” oor in order to install drain joint.(As show in Fig.18)
(4) For the unit with cooling capacity of 2300W~5000W, 6
expansion screws are needed; for the unit with cooling capacity
of 6000W~8000W, 8 expansion screws are needed; for the
unit with cooling capacity of 10000W~16000W, 10 expansion
screws are needed.
(1) After tightening the screw, pull the power cord slightly to
check if it is “ rm.
(2) Never cut the power connection wire to prolong or shorten
the distance.
(1) The through-wall height of drain hose shouldn't be higher
than the outlet pipe hole of indoor unit.(As show in Fig.25)
(2) Slant the drain hose slightly downwards. The drain hose
can't be curved, raised and ” uctuant, etc.(As show in Fig.26)
Note:
Note:
Note:
The drain hos
can't raise
upwards
gas pipe
Liquid pipe
Liquid
valve
gas valve
Union nut
Pipe joint
Foot holes
Foot holes
8.6 Installation of Outdoor Unit
1. Fix the support of outdoor unit(select it according to the
actual installation situation)
(1) Select installation location according to the house structure.
(2) Fix the support of outdoor unit on the selected location with
expansion screws.
5. Connect Outdoor Electric Wire
(1) Remove the wire clip; connect the power connection wire
and signal control wire (only for cooling and heating unit) to the
wiring terminal according to the color; “ x them with screws.(As
show in Fig.23)
6. Neaten the Pipes
(1) The pipes should be placed along the wall, bent reasonably
and hidden possibly. Min. semidiameter of bending the pipe is
10cm.
(2) If the outdoor unit is higher than the wall hole, you must set
a U-shaped curve in the pipe before pipe goes into the room,
in order to prevent rain from getting into the room.(As show in
Fig.24)
(2) Fix the power connection wire and signal control wire with
wire clip (only for cooling and heating unit).
2. Install Drain Joint(Only for cooling and heating unit)
(1) Connect the outdoor drain joint into the hole on the chassis.
(2) Connect the drain hose into the drain vent.
(As show in Fig.19)
3. Fix Outdoor Unit
(1) Place the outdoor unit on the support.
(2) Fix the foot holes of outdoor unit with bolts.
(As show in Fig.20)
4. Fix Outdoor Unit
(1) Remove the screw on the right handle of outdoor unit and
then remove the handle.(As show in Fig.21)
(2) Remove the screw cap of valve and aim the pipe joint at the
bellmouth of pipe.(As show in Fig.22)
(3) Pretightening the union nut with hand.
(4) Tighten the union nut with torque wrench .
Hex nut diameter(mm)
Tightening torque(N.m)
ĭ
6
15~20
ĭ
9.52
30~40
ĭ
12
45~55
ĭ
16
60~65
ĭ
19
70~75
Refer to the following table for wrench moment of force
Fig.18
Fig.19
Fig.20
Fig.22
Fig.23
Fig.24
Fig.25
At least 3cm above the floor
Chassis
Outdoor drain joint
Drain hose
Drain vent
U-shaped curve
Wall
Drain hose
blue
violet
black
yellow-
green
Handle
Note: the wiring connect is for reference only,
please refer to the actual one
.
Wire clip
Wiring board
Grounding
wire
2
N
(1)
3
Connect to indoor unit
2
N(1)
3
handle
screw
Fig.21
Summary of Contents for ASH-09AIM PT
Page 1: ...SERVICE MANUAL ASH 09AIM PT ASH 13AIM PT MATRIX SERIE ...
Page 2: ......
Page 12: ...7 Technical Information Service Manual 596 354 838 899 303 378 550 Unit mm ASH 13AIM PT ...
Page 79: ......
Page 80: ...PARTS GUIDE MATRIX SERIE ASH 09AIM PT ASH 13AIM PT ...
Page 82: ...Service Manual Exploded View and Parts List ASH 09AIM PT ...
Page 84: ...Service Manual ASH 13AIM PT ...
Page 86: ...Service Manual Outdoor Unit ASH 09AIM PT ...
Page 88: ...Service Manual ASH 13AIM PT ...