Manual Control Mode
is indicated by the permanent illumination of a single red LED in the top of
the sensor head.
To switch the unit back into
Sensor Control Mode
, flick the internal wall switch/circuit breaker
off/on once within 1 second. The unit will return to
Sensor Control Mode
. This is indicated by the
return of the left to right scrolling LED's as described in
Sensor Control Mode
above.
TIME CONTROL MODE - SINGLE LED FLASHING
The benefit of
TIME CONTROL MODE
is that the user can program the unit to automatically
illuminate for a certain time, (1 - 8 hours) each night. At dusk the unit will illuminate for this set
period after which it will extinguish. The unit will then continue to operate in
Sensor Control Mode
when it senses movement until dawn. At dusk the following night the process will be repeated, the
unit will remain on for this set period (1 - 8 hours) then operate as a PIR unit until dawn.
TIME CONTROL MODE
Switch the internal wall switch/circuit breaker 3 times (off/on off/on off/on) within 3 seconds.
A single flashing red LED at the top of the sensor head indicates Time Control Mode.
The
unit will now illuminate for a user defined time between 1 and 8 hours. The time can be set by
rotating the centre adjustment knob as required. (See diagram G, the adjustment knob is identified
by the letter T inside a circle.)
Do not adjust this setting if you do not wish to use the Time Control Mode facility.
This time adjustment is factory set to 1 hour.
Please note: Fully anticlockwise is 1 hour, fully clockwise is 8 hours.
After the defined period has elapsed, the unit will return to
Sensor Control Mode
and operate as
previously set up and the three scrolling LED's will illuminate from left to right.
Time Control Mode
is differento to
Manual Control Mode
in that it will NOT reset to
Sensor
Control Mode
at dawn, it will repeat each night until reset by the user. To cancel
Time Control
Mode
, switch the internal wall switch/circuit breaker once (off/on) within one second. The unit will
turn to
Sensor Control Mode
indicated by the scrolling LEDs.
SECTION FIVE
TECHNICAL SPECIFICATIONS
Detection Range
Detection Angle
Power Supply
Maximum Switchable Load
Lamp Type
Time On Adjustment
Dusk Level Adjustment
Environmental Protection
Up to 12 metres
200º
220 ~ 240 V AC ~ 50Hz
2000W (4 x 500W Tungsten Halogen)
230V Linear Tungsten Halogen 500W max (R7S cap)
5 seconds - 5 minutes
Day & night or night only operation
IP44 (suitable for outdoor use)
LHT0090&91 251012:newnlht009091.qxd 10/26/12 5:17 PM Page 8