TEST MODE - 3 LEDS PARTIALLY VISIBLE
The lamp will now illuminate for approximately 5 seconds every time movement is detected.
Walk across the detection area approximately 5 metres from the unit. Each time you are detected
the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5
seconds)
Start moving again, when you are detected again the lamp will illuminate.
Repeat the above, walking at various angles and distances to the unit. This will help you to
establish the detection pattern.
If the detection area is too small for your requirements, try angling the sensor head up.
Angling the head downwards will reduce the detection area should a smaller range be required.
SETTING UP FOR SENSOR CONTROL MODE - 3 SCROLLING LED’S VISIBLE
When walk tests are complete, the unit will be switch into
Sensor Control Mode
.
Simply cease movement within the detection area for approximately 60 seconds,
ensure the
lamp is not illuminated
. The unit will then switch to
Sensor Control Mode
, this is indicated by
the illumination of three scrolling LEDS in the top transparent area of the sensor head. These
LED's will scroll from left to right during daylight and darkness.
The TIME setting controls how long the unit remains illuminated following activation and after all
motion ceases.
(See diagram G. the time adjustment knob is indicated by the "Clock" symbol).
The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully
clockwise) is approx. 5 minutes. Set the control to the desired setting between these limits.
The DUSK control determines the level of darkness required for the unit to start operating. The
setting is best achieved by the procedure below:
(See diagram G. the Dusk adjustment knob is indicated by the "Moon" and "Sun symbols).
Set the DUSK control knob fully anti clockwise. Wait until darkness falls.
When the ambient light level reaches the level of darkness at which you wish the lamp to
become operative (i.e.: at dusk) SLOWLY rotate the control in a clockwise direction until a point
is reached where the lamp illuminates. Leave the control set at this point.
At this position the unit should become operative at approximately the same level of darkness
each evening. Observe the operation of the unit. If the unit is starting to operate too early (i.e.:
when it is quite light) adjust the control slightly anti-clockwise. If the unit starts to operate too late
(i.e.: when it is very dark). Adjust the control slightly clockwise. Continue to adjust until the unit
operates as desired. The LED's will scroll from left to right, day and night; indicating the unit is in
Sensor Control Mode
. The LED's will extinguish when the PIR activates the light for as long as
the lamp is illuminated.
MASKING THE SENSOR LENS
To restrict the sensor coverage, preventing detection in unwanted areas, mask the sensor lens
using the masks provided in the accessory pack (see diagram H). For your information, the top
section of the lens covers long range detection, the bottom covers short range. Similarly the left
and right lens sections cover the left and right detection areas respectively.
SETTING UP FOR MANUAL CONTROL - SINGLE LED ILLUMINATED
The light can be switched on for longer time periods by use of the
Manual Control Mode
. This
can be activated at night by using the internal wall switch or circuit breaker.
Switch the internal wall switch/circuit breaker twice (off/on, off/on) within 2 seconds. The unit will
now illuminate continuously until it is switched back into
Sensor Control Mode
or until the unit
automatically resets itself into
Sensor Control Mode
at dawn.