www.ivalolighting.com
610.282.7472
Ivalo Finiré 4” LED Recessed Lighting
Installation Instructions
367-2202
h
1 05.31.16
Important Notes
• IC fixtures must be used for installations containing insulating materials
and must be mounted away from heat producing elements (e.g., HVAC
ducts, hot water pipes, radiant heat floors, ovens). Non-IC fixtures
cannot be used in these types of applications.
• Non-IC fixtures are intended for free air applications. Do not confine
non-IC fixtures with insulation or building materials.
• Leads in junction box are ready for connection.
• Contractor is responsible for power connection.
• The mud ring shipped with trimless fixtures must be installed to ensure
desirable ceiling aesthetic.
• Thermal protection device standard on non-IC housing fixtures (voltage
specific device: 120 V
~
or 277 V
~
).
• 14 W and 17 W IC fixtures are 11.1 in (282 mm) long.
18 W and 20 W IC fixtures are 17.3 in (439 mm) long.
17 W, 18 W and 20 W Non-IC Fixtures are 11.1 in (282 mm) long.
See
Dimensions
.
• Mounting brackets can be installed on either side of the fixture.
• Prior to fixture installation, remove cable tie securing light module to the
fixture housing.
Fixture Installation
1. Turn off power.
WARNING: Shock Hazard.
Serious injury or death may occur.
Turn off power before servicing or installing. Wire according to local
and national codes. This product should be installed by a qualified
electrician.
2. Install fixture using the mounting bar based on mounting method
(Figure 1)
. Mounting brackets can be installed on either side of the
fixture.
a. Insert mounting bar into mounting bar clamp.
b. Use mounting bar to secure to structure (notch allows for T-bar
installation). Secure wires to mounting bar
(if required).
c. Hammer barb into stud. Secure with mounting screws provided by
others.
3. To adjust mounting bar position
(Figure 1 & 2)
:
a. Loosen both mounting bar clamp set screws
b. Adjust mounting bar to desired position
c. Tighten mounting bar clamp set screws
4. Make power connections.
See
Circuit Diagrams for Dimming
.
5. Cut out drywall to fit fixture aperture.
a. Round diameter: 4.7 in (119 mm)
b. Square dimensions: 4.8 in x 4.8 in (122 mm x 122 mm)
6. For adjustable fixtures, aim fixture at desired location
(Figure 2)
.
a. Loosen rotation-locking thumb screws.
b. Aim fixture by rotating the module support bracket to the desired
position.
c. Tighten thumb screws.
Dimensions
IMPORTANT INFORMATION
Please Read Before Installing
Figure 1
Module
support
bracket
Rotation-locking
thumb screw
Mounting
bar clamp
set screw
Note:
Enclosure and driver removed for visual clarity.
Figure 2
IC Housing
Non-IC Housing
Wire
Mounting
bar
Mounting
bar clamp
Barb
T-bar
notch
Leads and
ground
bundled
in junction
box.
Clip
11.1 in
(282 mm)
17.3 in
(439 mm)
9.5 in
(241 mm)
5.9 in
(150 mm)
11.1 in
(282 mm)
9.5 in
(241 mm)
4.2 in
(107 mm)