Important Notes

•  IC fixtures must be used for installations containing insulating materials 

and must be mounted away from heat producing elements (e.g., HVAC 
ducts, hot water pipes, radiant heat floors, ovens). Non-IC fixtures 
cannot be used in these types of applications.

•  Non-IC fixtures are intended for free air applications. Do not confine 

non-IC fixtures with insulation or building materials.

•  Leads in junction box are ready for connection.
•  Contractor is responsible for power connection.
•  The mud ring shipped with trimless fixtures must be installed to ensure 

desirable ceiling aesthetic.

•  Thermal protection device standard on non-IC housing fixtures (voltage 

specific device: 120 V

~

 or 277 V

~

).

•  14 W and 17 W IC fixtures are 11.1 in (282 mm) long.  

18 W and 20 W IC fixtures are 17.3 in (439 mm) long.  
17 W, 18 W and 20 W Non-IC Fixtures are 11.1 in (282 mm) long. 
See 

Dimensions

.

•  Mounting brackets can be installed on either side of the fixture.
•  Prior to fixture installation, remove cable tie securing light module to the 

fixture housing.

Fixture Installation

1.  Turn off power.

WARNING: Shock Hazard. 

Serious injury or death may occur. 

Turn off power before servicing or installing. Wire according to local 
and national codes. This product should be installed by a qualified 
electrician.

2.  Install fixture using the mounting bar based on mounting method 

(Figure 1)

. Mounting brackets can be installed on either side of the 

fixture.

a.  Insert mounting bar into mounting bar clamp.
b.  Use mounting bar to secure to structure (notch allows for T-bar 

installation). Secure wires to mounting bar  
(if required).

c.  Hammer barb into stud. Secure with mounting screws provided by 

others.

3.  To adjust mounting bar position 

(Figure 1 & 2)

:

a.  Loosen both mounting bar clamp set screws
b. Adjust mounting bar to desired position
c. Tighten mounting bar clamp set screws

4.  Make power connections.

 

See 

Circuit Diagrams for Dimming

.

5.  Cut out drywall to fit fixture aperture.

a.  Round diameter: 4.7 in (119 mm)
b.  Square dimensions: 4.8 in x 4.8 in (122 mm x 122 mm)

6.  For adjustable fixtures, aim fixture at desired location 

(Figure 2)

.

a.  Loosen rotation-locking thumb screws.
b.  Aim fixture by rotating the module support bracket to the desired 

position.

 c. Tighten thumb screws.

Dimensions

IMPORTANT INFORMATION
Please Read Before Installing

Figure 1

Module 

support 

bracket

Rotation-locking 

thumb screw

Mounting 

bar clamp 

set screw

Note:

 Enclosure and driver removed for visual clarity.

Figure 2

IC Housing

Non-IC Housing

Wire

Mounting 

bar

Mounting 

bar clamp

Barb

T-bar 

notch

Leads and 

ground 

bundled 

in junction 

box.

Clip

11.1 in

(282 mm)

17.3 in

(439 mm)

9.5 in

(241 mm)

5.9 in

(150 mm)

11.1 in

(282 mm)

9.5 in

(241 mm)

4.2 in

(107 mm)

Summary of Contents for Ivalo Finire

Page 1: ...e according to local and national codes This product should be installed by a qualified electrician 2 Install fixture using the mounting bar based on mounting method Figure 1 Mounting brackets can be installed on either side of the fixture a Insert mounting bar into mounting bar clamp b Use mounting bar to secure to structure notch allows for T bar installation Secure wires to mounting bar if requ...

Page 2: ...ded by others into holes in mud ring and screw into fixture Screw length depends on ceiling thickness b Use screws to level c Ensure screws secure mud ring flush to drywall d Apply plaster up to rim of mud ring e Smooth plaster to blend with ceiling 9 Install trim Figure 5 a Trimmed round and square and trimless round i Compress torsion springs at sides of trim ii Slide into trim brackets iii Allo...

Page 3: ... Figure 8 a Remove the trim Refer to step 1 and 2 above b Hold reflector by edges Twist counter clockwise to unlock from the light module c Carefully remove reflector d Install new reflector Twist clockwise to lock into light module 4 Field Replace Light Module Figure 9 a Follow steps 1 and 2 to remove the trim and reflector b Squeeze both light module clips and pull light module out of the module...

Page 4: ...D Driver with Soft on Fade to Black3 Mounted in Grounded Fixture To LEDs4 To LEDs4 1 Neutral may be optional for certain control types See control specification submittal for specific wiring diagrams 2 Refer to the specific Lutron control specifications for exact input voltage rating of the product 3 40 W maximum rated drivers 4 LED connectors are specific to LED module type Follow product guideli...

Page 5: ...s own expense CAN ICES 005 A NMB 005 A All Other Models Class B This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation Modifications not expressly approved by Lutron Electronics Co Inc could void the user ...

Reviews: