ELECTRICAL RATINGS
INPUT POWER: 12OV AC 60Hz
MOTOR OUTPUT MAXIMUM: 8AMPS
FUSED: 8AMP 125V
LOW VOLTAGE SUPPLY FOR OFF BOARD CONTROLS: 12VDC @250mA
DIAGNOSTIC LED’S
GREEN POWER LED ON - POWER AND FUSE CONNECTIONS ARE GOOD
YELLOW STOP LED ON - ACTIVE STOP SIGNAL (CONTROL IS LOCKED)
RED SAFETY LED ON - ACTIVE REVERSING DETECTOR SIGNAL. (CONTROL WILL LOCK DOOR IN OPEN
DIRECTION)
TROUBLE SHOOTING
PROBLEM - NO RESPONSE FROM CONTROL
1) IF THE GREEN POWER LED IS NOT ON: CONFIRM THAT THERE IS 120VAC ON THE POWER INPUT AND THAT
THE CONNECTIONS ARE CORRECT.
CHECK THE FUSE.
2) IF THE GREEN POWER AND YELLOW STOP LEDS ARE ON: CHECK THAT THE STOP JUMPER IS CONFIGURED
CORRECTLY.
CHECK CONNECTIONS TO THE STOP BUTTON.
3) IF THE GREEN POWER LED IS ON AND THE YELLOW STOP AND RED SAFETY LED’S ARE OFF: CHECK THE
CONNECTIONS TO THE MOTOR.
TEST THE MOTOR DIRECTLY WITH A TEST SWITCH.
CHECK THE MOTOR LIMITS (TURN BOTH LIMITS PLUS 5 REVOLUTIONS).
PROBLEM - MOTOR LOCKED IN ONE DIRECTION
1) IF THE RED SAFETY LED IS ON: CHECK THE CONNECTIONS TO THE REVERSING DETECTORS.
CONFIRM THAT THE JUMPERS JP3 AND JP4 ARE CONFIGURED CORRECTLY.
2) IF THE RED SAFETY LED IS NOT ON: CHECK THE CONNECTIONS TO THE MOTOR.
CHECK THE MOTOR LIMIT (TURN IT PLUS 5 REVOLUTIONS).
TEST THE MOTOR DIRECTLY WITH A TEST SWITCH.
PROBLEM - MOTOR RUNS ONLY AS LONG AS SWITCH IS HELD DOWN
THIS IS CORRECT OPERATION IF REVERSING DETECTORS ARE NOT USED. IF REVERSING DETECTORS ARE USED,
CHECK THE POSITION OF THE RUN TIME JUMPER (JP1 TOP).
INSTALLERS MANUAL
PAGE: 5 OF 5