POWER INPUTS:

  

G - GROUND

                                 N - 120 VAC NEUTRAL
                                  L - 120VAC HOT

POWER INPUTS:

  

MOTOR INPUTS:

 G - MOTOR GROUND (GREEN)

                                 N - MOTOR NEUTRAL (WHITE)
                                 U - MOTOR UP (BLACK*)
                                 D - MOTOR DOWN (RED*)
*IF MOTOR RUNS IN WRONG DIRECTION, REVERSE
THE RED AND BLACK MOTOR WIRES

MOTOR INPUTS:

HIGH VOLTAGE CONNECTIONS

MOTOR INPUTS

MOTOR INPUTS

POWER INPUTS

POWER INPUTS

JUMPERS

JP1

N

C

N

C

N

O

N

O

M

O

M

C

O

N

T

JP1

N

C

N

C

N

O

N

O

M

O

M

C

O

N

T

RUN TIME JUMPER JP1 (TOP)

JUMPER ON (MOM)

WITH THE JUMPER ON, THE RUN TIMER IS OFF AND THE 
SMC WILL DRIVE THE MOTOR ONLY AS LONG AS THE UP 
OR DOWN BUTTON IS PRESSED

NOTES:
1) THE REVERSING DETECTOR CONTROLS ARE 
DEACTIVATED IN THIS MODE.
2) THE SEQUENCING CONTROL IS DEACTIVATED IN THIS 
MODE.
3) THIS MODE CAN BE USED TO CLOSE THE DOOR IF 
THERE IS A MALFUNCTION IN THE REVERSING
DETECTORS. THIS MUST ONLY BE DONE IF THE 
UP/DOWN SWITCH IS IN DIRECT VIEW OF THE DOOR. 
THE REVERSING DETECTORS MUST BE SERVICED AS
SOON AS POSSIBLE AND THE DOOR RETURNED TO ITS
NORMAL OPERATING MODE. 

JUMPER OFF (CONT)

WITH THE JUMPER OFF, THE RUN TIMER IS ACTIVE AND 
THE SMC WILL DRIVE THE MOTOR FOR 1 MINUTE (OR 
TO THE MOTOR LIMIT) WHEN THE UP OR DOWN BUTTON 
IS PRESSED. PRESSING THE OTHER DIRECTION WHEN THE
MOTOR IS RUNNING WILL CAUSE THE MOTOR TO STOP 
FOR 1/4 SECOND BEFORE REVERSING DIRECTIONS.
.

NOTES:
1) THE SMC MUST BE IN THIS MODE FOR THE 
SEQUENCING AND REVERSING  DETECTORS TO BE 
ACTIVE.

INSTALLERS MANUAL 
PAGE: 1 OF 5

                   

SIMU U.S.INC

   6100 BROKEN SOUND PKWY. N.W., #14
              BOCA RATON, FL 33487
PHONE: 800-822-7468 

A

 FAX: 561-995-7502

Summary of Contents for SMC

Page 1: ...ports normally open and close inputs from reversing detectors ASupports 2 and 4 wire safety edges AThe stop button is selectable normally open or normally close QControl is selectable timed run or continuous pressure ASequencing input supports single contact devices such as Radio Controls Key Switches Card Readers The Smart Motor Control SMC is an ideal general purpose intelligent control system f...

Page 2: ...ECTOR CONTROLS ARE DEACTIVATED IN THIS MODE 2 THE SEQUENCING CONTROL IS DEACTIVATED IN THIS MODE 3 THIS MODE CAN BE USED TO CLOSE THE DOOR IF THERE IS A MALFUNCTION IN THE REVERSING DETECTORS THIS MUST ONLY BE DONE IF THE UP DOWN SWITCH IS IN DIRECT VIEW OF THE DOOR THE REVERSING DETECTORS MUST BE SERVICED AS SOON AS POSSIBLE AND THE DOOR RETURNED TO ITS NORMAL OPERATING MODE JUMPER OFF CONT WITH ...

Page 3: ...D WILL CAUSE THE SMC TO NOT OPERATE REVERSING DETECTOR JUMPERS JP3 JP4 JP3 JP4 JUMPERS OFF 4 WIRE EDGE BOTH JUMPERS JP3 AND JP4 MUST BE OFF TO USE A 4 WIRE SENSING EDGE NOTES 1 IF EITHER JUMPER IS OFF WITHOUT A 4 WIRE SENSING EDGE ATTACHED THE RED SAFETY LED WILL LIGHT AND THE DOOR WILL BE LOCKED IN THE UP DIRECTION BOTH JUMPERS JP3 AND JP4 SHOULD BE ON IF A NORMALLY OPEN REVERSING SENSOR IS USED ...

Page 4: ...UTTON STATION SEQ SEQ 12 12 GND GND N O SEQ SEQ 12 12 GND GND 1 2 3 RED WHITE BLACK RECEIVER SEQUENCING CONTROL SINGLE CHANNEL RADIO NOTES 1 CAN BE USED WITH ANY MOMENTARY DRY CONTACT SUCH AS KEY SWITCHES CARD READERS RADIO CONTROLS ETC 2 TWO OR MORE SWITCHES CAN BE WIRED IN PARALLEL 3 CONTROL WILL FOLLOW A SEQUENCE WITH EACH PULSE UP STOP DOWN STOP UP NOTES 1 WIRING SHOWN IS STANDARD BUT MAY VARY...

Page 5: ...ES UPON SENSING EDGE ACTIVATION WHEN THE DOOR IS GOING UP INSTEAD OF DOWN REVERSE THE RED AND BLACK MOTOR LEADS JP1 JP1 N O SENSING EDGE 2 WIRE JP3 JP4 N O SE2 SE2 SE1 SE1 NC NC NO NO MOM MOM CONT CONT JP1 JP1 NOTES 1 JUMPER JP3 MUST BE ON AND JP4 MUST BE OFF WHEN USING NORMALLY CLOSE REVERSING SENSOR 2 JP1 TOP JUMPER MUST BE OFF CONT THIS SETS THE SMC RUN TIMER ON 3 JP1 LOWER JUMPER SETTING DEPEN...

Page 6: ... AND YELLOW STOP LEDS ARE ON CHECK THAT THE STOP JUMPER IS CONFIGURED CORRECTLY CHECK CONNECTIONS TO THE STOP BUTTON 3 IF THE GREEN POWER LED IS ON AND THE YELLOW STOP AND RED SAFETY LED S ARE OFF CHECK THE CONNECTIONS TO THE MOTOR TEST THE MOTOR DIRECTLY WITH A TEST SWITCH CHECK THE MOTOR LIMITS TURN BOTH LIMITS PLUS 5 REVOLUTIONS PROBLEM MOTOR LOCKED IN ONE DIRECTION 1 IF THE RED SAFETY LED IS O...