EN
4/7
S1
S2
S1
S2
WIRING
SIMUBOX motors for sectional doors have been made to be exclusively wired with 1.5 mm² diameter cables for the
power supply connection and with 0.75 mm² diameter cables for the command connection.
Attach the cables to prevent contact with moving parts.
- The installer must ensure that the installation of the motorization complies with the electrical installation instructions
in force in the country of commissioning.
- Always make a loop on the power cable to prevent water penetration into the actuator.
- Cables passing through a metal wall must be protected and insulated by a sleeve or sheath.
- The motor casing must be connected to a rigid conduit.
- Use the traction stop.
- The connection of the power supply conductors must be carried out after the motor has been installed on its support.
- Cables have to be stripped on 8 mm.
5
1
2
3
4
4.2 - Mounting of chain manual override
1. Remove the chain cover by
unscrewing the 4 screws.
2. Install the chain.
3. Pass the chain links in the
chain guide and in the notched
wheel by introducing them in.
4. Replace the cover.
For SIMUBOX single-phase, SIMUBOX three-phase and SIMUBOX EI three-phase:
There are 2 auxiliary contacts available which allow, for example, to know if the door is in open or closed position.
Outputs are made on a 3 terminal connector which is fixed on the cover plate.
Outputs of auxiliary contacts on 3 terminal connector :
• 1 terminal Ri S1 for S1
• 1 terminal Ri Com for common
• 1 terminal Ri S2 for S
Type of output : dry contacts normally open
Capacity : 1A under 24Vdc