background image

085

VARIABLE SPEED USER MANUAL

Premium Efficiency Variable Speed Motor 

Summary of Contents for 26-2215

Page 1: ...085 VARIABLE SPEED USER MANUAL Premium Efficiency Variable Speed Motor ...

Page 2: ...demarks and registered trademarks are the property of their respective companies The information in this document incorporates proprietary rights and is not to be duplicated wholly or in part without the express written permission of Regal Beloit Corporation and or Regal Beloit America Inc March 2016 USA ...

Page 3: ...and Function Overview 12 6 2 User Interface Key Pad Overview 13 6 3 Set the Schedule 13 6 4 Running VGreen 085 from Key Pad 15 6 5 OVERRIDE 17 6 6 Schedule Advance 18 6 7 Key Lockout 20 6 8 Motor Pause 21 6 9 Temporary Stop with Digital Serial Input 21 6 10 Reset Factory Defaults 22 7 Priming 22 8 Freeze Protection 22 9 Control with Digital Inputs 23 10 DIP Switches 24 11 Care and Maintenance 25 1...

Page 4: ...ANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE identifies potential equipment damage or failure conditions an...

Page 5: ...grated electronics interface controls the speed settings as well as the run durations The VGreen 085 can run at speeds ranging between 600 and 3450 RPM and is rated for 115 Vrms at an input frequency of 60 50 Hz 2 Navigation Overview Increases decreases selected value Pressing any key following a change accepts the current value displayed inside the setting Figure 1 VGreen 085 User Interface Butto...

Page 6: ...ctromechanical motor and control design Benefits of adding an optional VGreen 270 user interface with the VGreen 085 motor Ability to conduct field troubleshooting i e view FAULT codes and real time operating parameters Ability to set a pump running schedule based on a real clock setting i e must input actual time which then determines pump start and stop times Ability to remotely mount the VGreen...

Page 7: ...T key will start the VGreen 085 based on the factory default schedule NOTE If power is cycled to the VGreen 085 and the user does not press the STOP key the VGreen 085 will automatically start and run the programmed default schedule shown in the chart above This feature ensures that the VGreen 085 will re start in the event of a power outage Button Duration In Hours Speed In RPM STEP 1 4 3100 STEP...

Page 8: ...ss the STEP 1 key The STEP 1 button and DURATION setting LEDs will illuminate The bar graph will show default DURATION for STEP 1 1 Press UP or DOWN arrows to change the DURATION 2 Press the STEP 1 key again to change the SPEED setting The SPEED setting LED will illuminate The bar graph will show default SPEED for STEP 1 3 Press UP or DOWN arrows to change the SPEED 4 Press any STEP or OVERRIDE ke...

Page 9: ...program a schedule with a combined dura tion for all three steps greater than 24 hours the VGreen 085 software will retain the current STEP time duration only and will zero out the other two STEP time settings As an example if STEP 1 equals eight 8 hours STEP 2 equals nine 9 hours and STEP 3 equals eight 8 hours for a combined 25 hours the VGreen 085 will retain the setting for the current Step be...

Page 10: ...maintain proper filtration to achieve satisfactory sanitation The User Interface is located on top of the VGreen 085 To the right of the STEP buttons is the OVERRIDE button This button can be used to operate the VGreen 085 at speeds outside of the normal operating schedule Figure 2 VGreen 085 Overview DIP Switch Serial Connector Digital Inputs Mains Connections Keypad Buttons NOTICE The VGreen 085...

Page 11: ... to a length of approxi mately 0 33 The terminal block is capable of handling solid or stranded wire up to 12 AWG in size The screw for the mains connections should be properly tightened to a torque value of 10 in lb Pin Wire Color Description L1 Black Hot 1 L2 Red or White Hot 2 Green screw Green Earth Table 1 Mains Connection Pin Wire Color Description J201 1 Red 12V J201 2 Black A J201 3 Yellow...

Page 12: ...2 RED OR WHITE EARTH L1 BLACK 115V POWER SOURCE Power should be turned off when installing servicing or repairing electrical components Observe all warning notices posted on the existing equipment VGreen 085 and in these installation instructions ...

Page 13: ...R RIDE pin 4 COMMON pin 5 Vac or VDC GND EXTERNAL SUPPLY Automation System or Solar System Controller VGreen 085 Controller Figure 5 Digital Input connector Access to these terminals is in close proximity to the mains connectors which carry line voltage capable of causing personal injury or damaging the equipment if contact is made Power should be turned off when accessing this area ...

Page 14: ...d SPEED Blinking 1 sec Solid ON Indication Key for LEDs V Green 165 UI LED Indication and respective functionalities Serial Communication Functions X LED Function Power START FAULT STEP1 STEP2 STEP3 OVERRIDE SPEED SETTING DURATION SETTING BARGRAPH Power On X Step1 X X X Step2 X X X Step3 X X X Override X X X Keypad lock X Keypad Unlock X X X X Schedule Advance X X X Restore Default settings X All ...

Page 15: ... the VGreen 085 is 3450 RPM and the lowest is 600 RPM Unless a new user defined schedule is entered the VGreen 085 will operate based on the following factory default schedule If power is connected to the VGreen 085 motor pressing any of the following buttons referred to in this section 6 2 could result in the motor starting Failure to recognize this could result in personal injury or damage to eq...

Page 16: ...e STEP currently being set will always take priority over any previous settings In the event a user attempts to program with a combined duration greater than 24 hours the current STEP setting will be retained whereas the other two STEP settings will be cleared to zero hours requiring the user to reset them Prior to beginning the actual programming process it is advisable for the user to review the...

Page 17: ...FF state including when it automatically restarts following a power outage The default Prime setting is defined in the Priming section of this document 3 The VGreen 085 then starts running in STEP 1 at the programmed DURATION and SPEED The ACTIVE LED for STEP 1 will turn ON The DURATION and SPEED setting LEDs along with the re spective bar graph LED will blink back and forth every three 3 seconds ...

Page 18: ...ing normal schedule operation the 24 hour schedule will stop When START is pressed again the 24 hour schedule will start from STEP 1 NOTE If power is lost while the VGreen 085 is running a 24 hour sched ule upon restoration of power the VGreen 085 will start the 24 hour schedule from STEP 1 NOTE If a digital input provided from an external source is detected the VGreen 085 will start running on th...

Page 19: ... its respective bar graph LED will blink back and forth at three 3 second intervals 2 The UP DOWN arrows allow the user to configure OVER RIDE DURATION and SPEED These settings can be changed while the VGreen 085 is running These settings are stored each time the UP DOWN arrows are pressed NOTE When the OVERRIDE duration ends the VGreen 085 resumes the 24 hour schedule at the point in the currentl...

Page 20: ... time of the day with the 24 hour schedule starting at a different time of day The VGreen 085 can run in the Schedule Advance mode by using the OVERRIDE button and upon completion will begin the programmed 24 hour schedule at STEP 1 DURATION and SPEED The following steps should be followed to set Schedule Advance mode 1 With the VGreen 085 stopped press and hold the START key for more than three 3...

Page 21: ...ow the user to run the VGreen 085 during the period of the Schedule Advance mode NOTE While the VGreen 085 is in the Schedule Advance mode if a user presses STEP 1 STEP 2 STEP 3 or the START key the system will start the normal schedule and the Schedule Advance mode will be canceled NOTE While the VGreen 085 is in the Schedule Advance mode if a user presses the STOP key then the Schedule Advance m...

Page 22: ...P 2 and STEP 3 will illuminate temporarily indicating the keypad is un locked NOTE While operating in key lockout mode the motor can still be stopped by pressing the stop key If no digital or serial input is present the motor will remain stopped If the motor is being controlled by a digital or serial input the motor will only temporarily stop for 4 minutes See section 6 9 for more information on t...

Page 23: ...en being controlled by a serial or digital input The user can press the STOP button while the VGreen 085 is running and the VGreen 085 will stop and stay off for four 4 minutes Once this time has elapsed the VGreen 085 will return to normal operation and accept an input from digital or serial input source Refer to section 9 for additional details on digital inputs NOTE If the VGreen 085 is operati...

Page 24: ...set threshold the VGreen 085 will automatically turn on assuming the START button has been pressed and circulate the pool water The Freeze Protection will run according to the following conditions utilizing the factory default settings Freeze Protection turn ON temperature 39 F Freeze Protection Duration 1 Hour By utilizing the VGreen 270 user interface accessory sold separately these factory defa...

Page 25: ...hen a digital input is present NOTE A generic wiring diagram is provided in figure 7 for connecting the VGreen 085 to a System Level Controller This concept can be ap plied to a solar system or any other type of control system NOTE There is no schedule for digital inputs The timing for each speed is controlled directly by the digital inputs NOTE The digital inputs have the highest priority amongst...

Page 26: ...the equipment if contact is made Power should be turned off when accessing this area The DIP switches can be used to configure different settings for the VGreen 085 Each DIP switch and their corresponding function is de fined in Table 5 Access to these terminals is in close proximity to the mains connectors which carry line voltage capable of causing personal injury or damaging the equipment if co...

Page 27: ...art automatically fol lowing the FAULT cycle ac power to the VGreen 085 and wait five 5 minutes If this does not correct the situation please contact Customer Service at 1 800 262 6484 The VGreen 085 reads the FAULT status and provides feedback to the user via the FAULT LED The VGreen 085 will illuminate the FAULT LED when a FAULT is present The VGreen 085 will stop and remain OFF when the FAULT i...

Page 28: ... remain illuminated 3 When a FAULT is present and the FAULT LED is illuminated only the STOP key will function The remaining buttons become disabled 4 When the FAULT LED is continuously ON i e not blinking a FAULT is present in the controller When the FAULT LED is blinking every one 1 second a FAULT is present in the user interface 5 When the FAULT has cleared the FAULT LED will turn OFF 6 Once th...

Page 29: ...V AC 24V AC 20 or 9 30V DC 12 24V DC 20 Auxiliary Load Terminals N A Maximum Continuous Load 0 85 THP Total Horse Power Speed Range 600 3450 RPM Environmental Rating NEMA Type 3R Agency Approval R C XDNW2 E302804 R C XDNW8 E302804 Ambient Conditions Storage 40ºC to 85ºC 40ºF to 185 Operating 0ºC to 40ºC 32 F to 104 F Humidity Relative 0 to 95 non condensing ...

Page 30: ...nt Over temperature FAULT Debris in strainer basket Air leak User Interface is not connected Over current FAULT Loose mounting Clogged or restricted plumbing VGreen 085 shaft is locked VGreen 085 shaft is damaged VGreen 085 will automatically restart after one 1 minute Check that mounting bolts of VGreen 085 and pump are tight Check for blockage in strainer or suction side piping Checked for block...

Page 31: ...right 2016 The text and images in this document are not to be modified without express written permission of Regal Beloit Corporation and or Regal Beloit America Inc Regal Beloit America Inc 531 North Fourth Street Tipp City OH 45371 Fax 937 667 5030 www centuryelectricmotor com Customer Service 1 800 262 6484 Please refer to our website www pool motors com for updates to this printed manual ...

Page 32: ...Distribution Marketing 1325 Heil Quaker Blvd LaVergne TN 37086 Phone 866 887 5216 Fax 800 468 2062 www pool motors com 2016 Regal Beloit Corporation 10019877 001 001 3 16 ...