Activation of relays:
Each relay can be activated on one or several following conditions:
•
Alarm
•
Fault
•
Inhibition
Factory setting:
•
Relay 1:
normally open (not energized) activated on alarm levels
•
Relay 2:
normally closed (energised) activated by any fault or inhibition
This menu
allows you to switch
the
format of the output
current between
4-20 mA
and
0-22
mA.
6.8.5.
[INH]ibition submenu
Maintenance inhibition can be configured in « frozen » mode (Factory setting) or « free »
mode.
•
In « frozen» mode, the outputs (current and relay) remain in their previous state.
For example, if the device displays a fault (2.0 mA), it will remain in this mode during
the inhibition
•
If the device is configured in « free » mode, the current output will remain at the
same level than the permanent inhibition
6.9.
Maintenance menu [MAIN]
The maintenance menu allows the user to check if the detector is in normal operation
conditions
•
(Test of the relay and current outputs).
6.9.1.
[TEST] sub-menu
6.9.1.1.
Relay menu
This menu gives access to activation or deactivation of the relays.
The detector switches to inhibition mode. The detector will stay in inhibition mode if the user
goes back through the steps to the main menu. Otherwise, the detector will return to its
“current” state.
6.9.1.2.
The 4-20 mA screen
This menu allows the output current to be set at a chosen value. The possible output values
are: 2mA, 4mA, 8mA, 12mA, 16mA, 20mA or 22mA.
During this phase, the detector switches automatically to inhibition mode. The detector will
stay in inhibition mode if the user goes back through the steps to the main menu. Otherwise,
the detector will return to its “current” state.
6.9.2.
NETWORK sub-menu
This menu gives direct access to different tests for the network. For any further details,
please refer to the additional network operating manual:
•
SPIN sends the detectors network identification.
•
LIEN switches from normal mode to logic link mode.
•
SWITCH enables the switches to go on mode open/closed/open secured.
Summary of Contents for MultiTox DG-TT7-S
Page 1: ...Operating Manual NOSP 16452 05 03 2018 MultiTox Detector MultiTox DGi TT7 E DGi TT7 O DG TT7 S...
Page 2: ...MultiTox DGi TT7 E O DG TT7 S Page 2 60 NOSP 16452 05 08 2016...
Page 15: ...MultiTox DGi TT7 E O DG TT7 S Page 15 60 NOSP 16452 05 08 2016 Figure 2 Outline drawing mm...
Page 39: ...MultiTox DGi TT7 E O DG TT7 S Page 39 60 NOSP 16452 05 08 2016...
Page 54: ...MultiTox DGi TT7 E O DG TT7 S Page 54 60 NOSP 16452 05 08 2016 13 DECLARATION OF CONFORMITY...
Page 55: ...MultiTox DGi TT7 E O DG TT7 S Page 55 60 NOSP 16452 05 08 2016...
Page 56: ...MultiTox DGi TT7 E O DG TT7 S Page 57 60 NOSP 16452 05 08 2016...
Page 57: ...MultiTox DGi TT7 E O DG TT7 S Page 58 60 NOSP 16452 05 08 2016...
Page 58: ...MultiTox DGi TT7 E O DG TT7 S Page 59 60 NOSP 16452 05 08 2016...
Page 59: ......