background image

 
 

Operating Manual 

TRACSCAN 2.0 

 

 

 

 

Summary of Contents for TRACSCAN 2.0

Page 1: ...Operating Manual TRACSCAN 2 0...

Page 2: ...Operating Manual TRACSCAN 2 0 V2 0 2022 05 2 36...

Page 3: ...6 1 Operation 12 4 6 2 Content 13 4 6 3 User Roles 13 4 6 4 Program Settings 13 4 6 5 Instrument Settings 17 4 7 Archive 18 4 8 Operating Data 19 4 8 1 General 19 4 8 2 Counters and Hour Meters 19 4 8...

Page 4: ...Operating Manual TRACSCAN 2 0 V2 0 2022 05 4 36 8 7 Connection Settings 31 8 8 Options 32 9 Technical Data 33 Glossary 34 References 35...

Page 5: ...void standing water and splash water Never moisten the top side of the test foot see page 21 and do not sub merge the test foot To avoid wheel slip clean the wheels rubber rings before starting a meas...

Page 6: ...trument stores all measurements in a data archive This manual describes how to operate and maintain the instrument It also describes the Trac Man software This software allows data retrieval from the...

Page 7: ...he instrument on the walkway surface test tile pointing in the desired direction Ensure that the instrument can move along the entire path without obstruction 5 Start Measurement Start the measurement...

Page 8: ...Operating Manual TRACSCAN 2 0 V2 0 2022 05 8 36 4 Instrument 4 1 Overview Figure 1 TRACSCAN Top View...

Page 9: ...lt settings and how to change them Print results from most recent measurement see section 3 6 5 for default setting and how to change them Open the main menu for program and instrument settings see se...

Page 10: ...control panel shows the charging state Color Meaning Solid Green Battery fully charged Blinking Green Charging Solid Red Battery or charging fault see section 7 Table 1 Battery Charging LED 4 4 Print...

Page 11: ...Table 2 What to print 4 5 Location Code The user can assign so called location codes for the various locations where measurements have been performed This makes it possible to assign a measurement to...

Page 12: ...ng coun ters and various system data for diagnostics Figure 4 Main Menu If the menu system is open the functions of the 4 buttons are context sensitive and are shown as icons in the bottom bar of the...

Page 13: ...ator with read only access to program and instrument settings Role Supervisor with full access to program and instrument settings The roles are not protected by passwords but merely shall avoid misuse...

Page 14: ...of Samples Number of samples for average SCOF value Up to 10 samples are supported SCOF Distance Measurement distance Distances between 10 cm and 100 cm are supported DCOF TCOF Discard First Sample De...

Page 15: ...nt Yes Ramp Level Only Residence Time 0 1 s Number of Samples 5 Discard 1st Sample Yes Lift Lower Between Samples No Required Test Foot Type SBR see section 4 Table 7 Test Program NFSI B101 1 2020 Tes...

Page 16: ...Test Program NFSI 101 C Parameter Name Default Value Can be altered Scale Standard NFSI 101 C COF Type TCOF Wet Measurement No Ramp Auto Detect Distance 15 cm Required Test Foot Type SBR see section 4...

Page 17: ...ary inch unit Shut Down After Measurement Per default the instrument shuts down after a measurement has been taken To avoid delays while taking a series of measurements the instrument can be kept aliv...

Page 18: ...reports the local time is displayed The local time is defined by an UTC Offset e g 01 00 hour for Western European Time Date Format The instrument supports several date formats that define how the da...

Page 19: ...ged Events is described in sec tion 3 8 3 Menu Printout offers means to print all operating data on the printer or via USB 4 8 2 Counters and Hour Meters The following counters and hour meters are kep...

Page 20: ...0 2022 05 20 36 Traction Motor Run time of traction motor Table 13 Operating Data 4 8 3 Events The instrument stores up to 128 event records If the event log reaches its maximum size a new event will...

Page 21: ...ributor for renewing replacement or additional test feet Different liner materials test foot types are available SBR Recommended standard liner and required for all NFSI methods An SBR test foot can b...

Page 22: ...e cannot be restored using the man ual sanding as described above To ensure accurate results throughout the lifetime of the test foot it must be reconditioned using the test foot preparation tool see...

Page 23: ...n Tool is a hand operated sanding tool specially designed for use with the TRACSCAN 2 0 test foot It makes the task of sanding the test foot quick and easy and always precise matching the exact curve...

Page 24: ...the cut off edges facing to the left or right The correct arrangement is crucial see images below Figure 12 Test Foot OK Figure 13 Test Foot Wrong 4 Gently re insert the circular cover into the tool...

Page 25: ...s less than 11 V Charge battery Traction Motor Fault Traction motor cannot move as in tended Turn off instrument Check if rear wheels can be turned freely Test Foot Motor Fault Test foot motor cannot...

Page 26: ...is plugged properly Make sure that the con tact pads are clean Test Foot Data In valid Test Foot has been detected but data could not be read or written Check if the test foot is plugged properly Mak...

Page 27: ...vice Record Not Available Requested measurement record cannot be found Turn off instrument and restart operation If fault still exists con tact service Internal Update Running Can occur right after a...

Page 28: ...port 8 3 Installation The installer for the program is distributed as msi file Windows Installer Package As the installer comprises an USB driver for the TRACSCAN 2 0 instrument administrator privile...

Page 29: ...USB port s for an instrument If an instrument is connected but is not found open Connection Settings see below Once an instrument has been found basic data of the connected instrument are displayed Id...

Page 30: ...ll available reports of the selected instrument Report View Displays the selected report TracMan can handle measurement reports of several instruments The instruments are distin guished by their seria...

Page 31: ...or the instrument s display controller see firm ware release notes the instrument automatically updates the display controller after it has been turned on for the first time after the firmware update...

Page 32: ...an the USB ports If an instru ment is found it will be shown in the drop down list If a device instrument is shown but was not displayed in the Start Center select the de vice in the drop down list an...

Page 33: ...for charging and data communication Bluetooth LE 5 1 for data communication Archive Size Up to 2048 measurements oldest record is overwritten if maxi mum size has been reached Printer Type Thermal pri...

Page 34: ...er A common material for the test foot liner Scale The scale that is used to visualize the Coefficient of Friction values If the scale is defined by a standard the scale also defines and shows thresh...

Page 35: ...101 0 Walkway Surface Auditing Procedure for the Measurement of Walkway Surface Traction NFSI B101 1 2020 National Floor Safety Institute B101 1 Test Method for Measuring the Wet SCOF of Hard Surface...

Page 36: ...Operating Manual TRACSCAN 2 0 V2 0 2022 05 36 36...

Reviews: