Simrad ES60
Dual beam (wide or narrow) transducer
This is the termination of the transducer cable from a single
frequency, dual beam transducer to the transducer socket on the
General Purpose Transceiver Unit (GPT). The other end of the
cable is permanently
fi
xed to the transducer.
Note
Always check the transmit power if wide beam is selected in
order not to exceed the power capacity on the transducer.
M
E
F
J
H
D
C
K
L
A
B
N
Transducer cable
Narrow
Transducer cable
Wide
Junction Box (1:1)
(Optional)
Junction Box (1:1)
(Optional)
GPT Transducer
socket
W802-3
Rev.E
Single frequency, dual beam (wide or narrow) termination
D
C
Screen
Connect to plug housing
Screen
Yellow/Green
Blue
Brown
Blue
Black
Connect to plug housing
D
C
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.
Related topics
Cable splicing
on page 140
Steel conduit
on page 140
GPT Transducer plug connection
on page 105
70