14 |
Wiring |
E5024 ECDIS Installation Manual
NMEA 0183 device connection
The E5000 processor has four NMEA 0183 ports; three for the ECDIS CPU, and one for the NSO
evo2 CPU. Each port supports bi-directional NMEA 0183 traffic. The NMEA 0183 port for the
NSO evo2 CPU may be configured for either NMEA 0183 or touch screen control. Both the
baud rate and sentences output by both CPUs are configurable.
1
2
3
4
key
connector/
name
colour
signal
CPU
serial
ECDIS
1
Serial 1 / 1B
brown
brown/white
green
green/white
NMEA 0183 RX_A
NMEA 0183 RX_B
NMEA 0183 TX_A
NMEA 0183 TX_B
ECDIS
TTYS1
2
Serial 1 / 1A
blue
blue/white
orange/white
orange
R
RS422_RX-
R
RS422_TX-
ECDIS
TTYS0
3
Serial 2 / 2B
brown
brown/white
green
green/white
NMEA 0183 RX_A
NMEA 0183 RX_B
NMEA 0183 TX_A
NMEA 0183 TX_B
ECDIS
Serial TCP
4
Serial 2 / 2A
blue
blue/white
orange/white
orange
R
RS422_RX-
R
RS422_TX-
NSO
¼
Note:
NMEA 0183 devices communicate at 4800 baud, while NMEA 0183 - HS devices com-
municate at 38,400 baud. Set the serial port baud rate to the same rate as used by the con-
nected equipment.
¼
Note:
AIS is not internally bridged, so it must be connected to one NMEA 0183 port on each
CPU if required on both screens.