| 11
Wiring |
E5024 ECDIS Installation Manual
Connecting monitors
Two displays may be connected to the E5000 via the HDMI ports.
The ECDIS CPU (HDMI 1 OUT) must be connected to a Simrad M5024 to conform to IMO
requirements.
The NSO evo2 CPU (HDMI 2 OUT) can connect to a wide range of supported monitors; the
Simrad DI-15, MO-L 15/17/19, MO16/19/24 (T&P), legacy MO-19, B&G ZM series, and KEPMGB-
15T.
It is possible to use third party monitors on the NSO evo2 CPU, however, these should
conform to the supported resolution and refresh rates defined in
“E5000 Processor
specifications” on page 38
.
¼
Note:
LCD monitors intended for home/office use are not designed to operate in areas
exposed to direct sunlight, and will appear dark and difficult to read. Also, unless carefully
ventilated and protected from moisture, their service life will be greatly compromised in the
marine environment.
Monitors with a HDMI input may be directly connected to the HDMI 2 output.
HDMI IN
HDMI IN
M5024 ECDIS
monitor
NSO evo2
monitor
¼
Note:
While the HDMI standard does not state maximum cable length, signal may be com-
promised on long runs. Only use Navico or other high quality HDMI certified cables. 3rd party
cables should be tested before installation. On runs over 10 m it may be required to add an
HDMI amplifier or use HDMI-CAT6 adaptors.