User Manual // Simpro Eurover
Original Instructions // English // v34.0 // April 2022 // Page
18
7.
Fix the Eurover into position with six M16 x 100-150mm sleeve anchors, in accordance
with the fixing manufacturer’s instructions.
Dynabolts
™
should be fixed in accordance with the instructions below:
8.
The Eurover is now installed, and can be detached from the lifting equipment.
4.1.3
Connecting the power
Electrical work should only be carried out by a certified electrician.
The recommend power supply for the standard Eurover is ~415VAC 50Hz 3-phase (±5%
voltage and ±1% hertz) with nominal capacity of at least 6 Amps.
For complete electrical specifications refer to the rating plate on the motor (see
).
1.
Depress the EMERGENCY STOP button.
2.
Connect the power plug to the socket at the base of the powerpack enclosure.
3.
Release the EMERGENCY STOP button.
4.
Press the RAISE button. If the cradle does not move, it is likely that the AC phase
polarity of the input current is inverted. The Eurover is fitted with a phase-rotation
relay, so it will not operate if the phasing is incorrect. Observe the following
procedures to rectify this problem:
a.
Depress the EMERGENCY STOP button
b.
Disconnect the power
c.
Have a
qualified electrician
switch over any two of the phase-wires in the
power plug.
d.
Repeat the process from step 2 above.
5.
Once machine is operating normally, proceed with commissioning.
4.1.4
Commissioning
Once the machine has been installed and connected to the power, it should be tested to
check for any operating faults or problems.