
Chapter 6: Power supply maintenance
43
Chapter 6: Power supply maintenance
This section contains the following topics:
•
About power supply maintenance guidelines
•
Remove a power supply
•
Install a power supply
Each server has two hot-swappable power supplies. If a power supply fails, replace it as soon as
possible.
About power supply maintenance guidelines
Follow these guidelines for maintaining power supplies:
■ You can replace a power supply without disrupting operations if an alternate, functioning power
supply is installed and connected to power.
■ For proper cooling, do not leave a power supply slot open. Do not remove a power supply until you
are ready to replace it.
■ A server can operate with only one functioning power supply. However, replace a failed or failing
power supply as soon as possible.
■ Replace a power supply only with a power supply of the same type and wattage. Contact
Customer
Support
for replacement power supplies.
Remove a power supply
You replace a failed, or failing, power supply as soon as possible.
Before you begin
You have completed these tasks:
■ Obtained a replacement power supply of the same type and wattage.
■ Read the guidelines for maintaining power supplies.
■ Read the guidelines for protecting hardware from electrostatic discharge.
Procedure overview
Please note the following information before you begin the procedure.