5
SimpliFire • SF-WM36, SF-WM58, SF-WM70, SF-WM94 Service Manual • 2040-908 Rev. D • 1/19
7. Locate replacement fan box. Plug the electrical
connector into the bottom of the appliance.
8. Locate the fan box to the bottom of the appliance so
that the fastener holes align.
9. Install all four screws between the fan box and the
appliance.
10. Install the glass front on appliance. Engage the tabs
on the two hanging brackets with the slots in the top
corner of the appliance. Push against the bottom
of the Glass Front to engage the plug connectors.
Install the two retainer screws between the Glass
Front mounting brackets and the appliance.
11. Connect the lighting LED harness to the appliance
harness.
Figure 17 (SF-WM36) Mounting Bracket
= Required Mounting Points
Wall Mounting Bracket
The wall mounting bracket must be used to mount the
appliance. This appliance must be mounted to a structur-
al wall capable of bearing a 40 pound load for SFWM36,
85 pound load for SF-WM58, 110 pound load for
SF-WM70, 135 pound load for SF-WM94.
Determine the desired location of the appliance on the
wall. Place the wall mounting bracket in the desired
location. Ensure that the bracket is level. Mark all loca-
tions on the wall that correspond to the required mounting
points in the bracket. See Figure 17 (SF-WM36),
Figure 18 (SF-WM58), Figure 19 (SF-WM70) or Figure
20 (SF-WM94).
Orientate the bracket so that its mounting hooks are
pointing up as shown in Figure 17 (SF-WM36), Figure
18 (SF-WM58), Figure 19 (SF-WM70) or Figure 20
(SFWM94). Fasten the bracket to the wall. The bracket
installation method varies depending on the wall con-
struction
Figure 18 (SF-WM58) Mounting Bracket
16 in.
16 in.
= Required Mounting Points
Note: For non-masonry walls, at least two mounting
points (screws 5x40) must align with a structural
framing member.
Figure 19 (SF-WM70) Mounting Bracket
= Required Mounting Points
Note: For non-masonry walls, at least two mounting
points (screws 5x40) must align with a structural
framing member.
Figure 20 (SF-WM94) Mounting Bracket
= Required Mounting Points
Note: For non-masonry walls, at least two mounting
points (screws 5x40) must align with a structural
framing member.
16 in.
16 in.
16 in.
16 in.
16 in.
16 in.
16 in.