background image

 

S4100-0035-6  4/2005

ALARM

FIRE

PULL    DOWN

ALARM

FIRE

PULL    DOWN

ALARM

FIRE

PULL    DOWN

ALARM

FIRE

PULL    DOWN

ALARM

FIRE

PULL    DOWN

ALARM

FIRE

PULL    DOWN

Second floor

Third floor

Fourth floor

Fifth floor

Sixth floor

Seventh floor

First floor

4100U Fire Alarm Control Panel

with Voice Control

MINIPLEX transponder

Speaker NAC

TrueAlarm sensors
and IDNet/MAPNET II
addressable circuits

Audio riser wiring,
twisted pair

RUI communications
wiring, twisted, shielded
pair

Legend:

ALARM

FIRE

PULL    DOWN

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

Press 

ACK 

l ocated under flashing indicator.

Repeat operation until all events ar e acknowledged.
Local tone w ill silence.

A B C

AC Powe r

D E  F

G H I

J K L

M  N O

P Q  R

'SP'  ( )

,  0 :

S  T U

V W X

Y  Z /

ALARMS

Fire Alarm

Priority 2 Alarm

SYSTEM WARNINGS

Supervisory

Trouble

Alarm Silen ced

Emergency Operating Instructions

Alarm or W arning Condition

How to Ac knowledge / View  Events

How to Silence Building Signals

System indicator flashing. Tone On .

Press 

Ala rm Silence.

How to Reset System

Press 

Sy stem Reset.

Press 

Ack 

to silence tone device.

ZONE

1

SI G

2

AUX

3

FB

4

IO

5

I DNet

6

P

7

A

8

L

9

NE T

ADDR

0

DEL

Enter

C/Exit

Fire Alarm

Ack

Priority 2

Ack

Supv
Ack

Trouble

Ack

Alarm
Silence

System
Reset

Event
Time

Enable

On
Arm

Disab le

Off

Disarm

Auto

Lamp
Test

More
Info

Menu

Previous

Next

SYSTEM IS NORMAL

08:23:43 am

MON 11-DEC-00

Fire Control

C
A
U
T
I
O
N

C

A

U

T

I

O

N

DISCONNECT
A. C.  POW ER

AND
BAT T ERY
BEF ORE
SERVI CING

DI SC

ON

N EC

T

A. C.

 P OW

ER

A ND

BA

TT

ER

Y

BE F

OR

E

SE RV

IC

IN

G

C
A
U
T
I
O
N

C

A

U

T

I

O

N

DISCONNECT
A. C.  POW ER

AND
BAT T ERY
BEF ORE
SERVI CING

DI SC

ON

N EC

T

A. C.

 P OW

ER

A ND

BA

TT

ER

Y

BE F

OR

E

SE RV

IC

IN

G

MINIPLEX transponder

Strobe NAC

Subject 

Data Sheet 

Subject 

Data Sheet 

Enclosures 

S4100-0037 

Basic Panel Modules and Accessories 

S4100-0031 

LED/Switch Modules 

S4100-0032 

Network Display Unit (NDU) 

S4100-0036 

4100U Audio/Phone Modules 

S4100-0034 

Remote Annunciators 

S4100-0038 

TrueAlert Addressable Products 

S4009-0003 

Remote Battery Charger 

S4081-0002 

IDNet+ Module with Quad Isolator 

S4100-0046 

 Typical Multi-Floor MINIPLEX Audio System 

 Additional 4100U Data Sheet Reference 

Summary of Contents for MINIPLEX 4100-9600

Page 1: ...n Off Auto PressACKlocatedunderflashingindicator Repeat operationuntil allevents areacknowledged Localtonew ill silence AB C AC Pow er D E F G H I J K L M N O P Q R SP 0 S T U VW X Y Z ALARMS F ire Al...

Page 2: ...sensors will alarm at a fixed temperature of 135 F 57 C x TrueAlarm device LEDs will be activated to indicate a device in alarm Local Mode Control Operation Continued Notification Operation Fire alar...

Page 3: ...ashing Tone On Press Ala rmSilence How to Reset System Press Sy stemReset Press Ack tosilence tone device ZONE 1 SIG 2 AUX 3 FB 4 IO 5 IDNet 6 P 7 A 8 L 9 NET ADDR 0 DEL Enter C Exit Fire Alarm Ack Pr...

Page 4: ...UL System Power Supply SPS 9 A power supply charger with 250 point IDNet channel 3 Class A B NACs and expansion slot for City Circuit or Alarm Relay option Canadian model has low battery cutout 4 Blo...

Page 5: ...Model Output Voltage 25 VRMS 70 7 VRMS Power Supply Input Listing Description Details 4100 1328 4100 1329 120 VAC 60 Hz UL 4100 1330 4100 1331 120 VAC 60 Hz ULC 4100 1332 4100 1333 220 230 240 VAC 50...

Page 6: ...102 MAPNET II Module 127 point capacity add devices separately Module size 2 Slots Loading per MAPNET II device 1 7 mA Fully loaded module total 470 mA 490 mA 4100 3103 Isolator Module for MAPNET II o...

Page 7: ...20 ft 6 1 m 2 Nine wires required 24 VDC 2 one per LED indicator 4 and one per switch 3 3 Wire size 18 AWG 0 82 mm Expansion Bay Module Loading Reference Description Mounting Transponder Interface Mo...

Page 8: ...r semi flush mounting 6 stud Optional semi flush trim kit reference Front view box outline without door Side view with door attached 2 Bay height 40 1016 mm Doors can be hinged left or right 3 Bay hei...