Overview

Specifications

Refer to the following environmental and power specifications:

Overview

The remote display assembly (RDA) is a surface-mounted version of the Flexible User Interface. The 
unit is mounted remotely from the FACP and wired back to it via remote unit interface (RUI) wiring. 
Since the printed circuit boards and LCD are factory-installed within the RDA enclosure, hardware 
installation consists of surface mounting the enclosure to the wall, and completing the RUI circuit 
connection. The 4100-9401 Flexible User Interface remote display assembly contains the following:

Flexible User Interface panel assembly

566-141 transponder interface card (TIC)

Remote box 13”X20.5”

 Figure 1. 4100-9401 Flexible User Interface Remote Display Assembly

Voltage

24V

Current Draw

186 mA Normal Standby

214 mA alarm

Temperature

32 to 120

o

F (0 to 49

o

C)

Humidity

Up to 93% (non-condensing) relative humidity at 90

o

F (32

o

C)

REMOTE BOX & DOOR

FLEXIBLE USER 
INTERFACE PANEL 
ASSEMBLY

TRANSPONDER INTERFACE 
CARD

firealarmresources.com

Summary of Contents for 4100-9401

Page 1: ...refer to the ES Panel Programmer s Manual 574 849 Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation manual These instructions must be followed to avoi...

Page 2: ...s of surface mounting the enclosure to the wall and completing the RUI circuit connection The 4100 9401 Flexible User Interface remote display assembly contains the following Flexible User Interface p...

Page 3: ...ce keyboard using harness 166 226 P2 Connects to LCD with matching connector P3 Connects to LCD to provide power P5 Allows direct connection of PC to Flexible User Interface controller for down loadin...

Page 4: ...card includes the following components LED 1 Reports communication loss with FACP Master when lit LED 2 Illuminates when a RUI ground fault search is active LED 4 Illuminates to indicate an RUI Style...

Page 5: ...nnecting the TIC to the controller card can be unplugged by pressing the tab at the end of the wire The nut and washer holding the grounding cable must be unscrewed 5 To completely remove the panel pr...

Page 6: ...n the Flexible User Interface controller card to P2 on the TIC card 5 Replace the door on its hinge and reattach grounding strap Configure Switch Address Switches SW1 on the Flexible User Interface Co...

Page 7: ...28 ON ON OFF OFF OFF ON ON 88 OFF ON OFF OFF ON ON ON 29 ON ON OFF OFF OFF ON OFF 89 OFF ON OFF OFF ON ON OFF 30 ON ON OFF OFF OFF OFF ON 90 OFF ON OFF OFF ON OFF ON 31 ON ON OFF OFF OFF OFF OFF 91 OF...

Page 8: ...ser Interface box from the CPU motherboard to the TIC All wiring is between 18 AWG and 12 AWG All wiring is supervised and power limited Maximum distance from the RUI controller to any RUI device is 2...

Page 9: ...for the wiring diagram to connect one or more Flexible User Interface s to a FACP Power must be supplied to the Flexible User Interface by connecting TB1 of the TIC to an auxiliary power tap Figure 7...

Page 10: ...ower the Flexible User Interface door assembly 3 Detach harness 734 008 from P2 of the TIC 4 Detach the green grounding straps connected to the studs on the back of the panel assembly by removing the...

Page 11: ...swivel standoffs extending in from the side panels of the bay see Figure 8 3 Loop the ring at the end of each grounding strap to the corresponding studs extending from the back of the door assembly Fa...

Page 12: ...579 687 Rev D firealarmresources com...

Reviews: