background image

 

IDNet Cards 

Installation Instructions 

 

©

 2003-2011 SimplexGrinnell LP. All rights reserved. 

Specifications and other information shown were current as of publication and are subject to change without notice. 

Simplex and the Simplex logo are trademarks of Tyco International Ltd. and its affiliates and are used under license.

 

 

574-800 

Rev. D

 

This publication describes the installation procedure for the following: 
 

 

4100-3101 IDNet Card – 250 Devices (742-476) 

 

4100-3104 IDNet Card – 127 Devices (742-817) 

 

4100-3105 IDNet Card – 64 Devices (742-818) 

 

4100-3106 IDNet Card w/Quick Connect capability – 250 Devices (742-954) 

 

4100-9811 IDNet Card – 250 Devices (Aftermarket) 

 

4100-9835 IDNet Card – 127 Devices (Aftermarket) 

 

4100-9836 IDNet Card – 64 Devices (Aftermarket) 

 
This product is compatible with 4100U and 4100ES Fire Alarm Control Panels (FACP). 
 

IMPORTANT:

   Verify FACP System Programmer, Executive, and Slave Software 

compatibility when installing, or replacing system components.  Refer to 

the Technical Support Information and Downloads website for 

compatibility information..  

 

Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage.  If 
damage is apparent, immediately file a claim with the carrier and notify Simplex. 
 

This publication discusses the following topics: 
 

Topic

 

See Page

 

Cautions, Warnings, and Regulatory Information 

Introduction to the IDNet Card 

Step 1: Installing the IDNet Card into the PDI 

Step 2: Setting DIP Switch SW1 

Step 3: Wiring to IDNet Peripherals 

Troubleshooting 

11 

 

Introduction 

Inspecting Contents 
of Shipment 

In this Publication 

Summary of Contents for 4100-3101

Page 1: ...ermarket 4100 9836 IDNet Card 64 Devices Aftermarket This product is compatible with 4100U and 4100ES Fire Alarm Control Panels FACP IMPORTANT Verify FACP System Programmer Executive and Slave Softwar...

Page 2: ...to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not...

Page 3: ...following LEDs LED1 Normally off Turns on steady if the IDNet card is not communicating with the 4100 CPU LED2 Normally off Illuminates to indicate a problem with the IDNet lines Steady on indicates...

Page 4: ...laves is normally 30 VDC Output is increased to 36 VDC when it is necessary to activate large numbers of output devices on IDNet peripherals such as piezo sounders The system CPU will set the output t...

Page 5: ...onnectors Use connector P2 labeled on the back side of the IDNet card to connect to any of the eight PDI connectors as shown in Figure 2 below Figure 2 Mounting onto the Power Distribution Interface S...

Page 6: ...llows SW1 1 This switch sets the baud rate for the internal 4100 communications line running between the card and the 4100 CPU Set this switch to ON SW1 2 through SW1 8 These switches set the card s a...

Page 7: ...FF OFF OFF 28 ON ON OFF OFF OFF ON ON 88 OFF ON OFF OFF ON ON ON 29 ON ON OFF OFF OFF ON OFF 89 OFF ON OFF OFF ON ON OFF 30 ON ON OFF OFF OFF OFF ON 90 OFF ON OFF OFF ON OFF ON 31 ON ON OFF OFF OFF OF...

Page 8: ...Net Card Wiring Lengths Wire Gauge Maximum Distance 18 AWG 7 14 Ohms 10 000 ft 16 AWG 4 59 Ohms 10 000 ft 14 AWG 2 82 Ohms 10 000 ft 12 AWG 1 77 Ohms 10 000 ft All wiring is supervised and power limit...

Page 9: ...ipheral IDNet appliance Note Use ferrite beads as shown 2 Route wire from the first IDNet appliance to the next one Repeat for each appliance 3 Route wire from the last IDNet appliance to the IDNetA a...

Page 10: ...G from the IDNetA IDNetA and SHIELD outputs on TB1 of the IDNet card to a junction box Begin T tapping at the junction box The maximum wiring distance for any IDNet circuit is 10 000 feet or 0 60 F Th...

Page 11: ...IDNet card is searching for earth faults on the IDNet line When this message is displayed the IDNet card cannot show any alarms or other statuses Appears when a short is detected on the IDNet channel...

Page 12: ...574 800 Rev D...