Power Supply Output Details:

 

 

RUI Communications

 

controls up to 10 remote devices 

at up to 2500 ft (762 m) for single run, or 10,000 ft 

(3048 m) total if wiring is Class B and T-tapped; output 

is selectable as Class B or Class A 

 

Compatible RUI remote equipment

 includes: 

4606-9202 and 4606-9205 Color Touchscreen 

Annunciators (up to 6 total), 4100 Series 24 I/O and 

LED/Switch modules, 4602 Series LED/Switch and I/O 

Annunciator modules, including 4602-9101 Status 

Command Units (SCU), and 4602-9102 Remote 

Command Units (RCU) 

 

IDNet+ SLC Output

 provides electrically isolated 

Class B or Class A communication; standard capacity is 

up to 100 addressable points with expansion for up to 

250 points using up to two 4007-9803 IDNet+ Loop 

Expansion Modules (as described on page 4)

 

 

 

Battery Charger

 is dual rate, temperature 

compensated, and charges up to 18 Ah sealed lead-

acid batteries in the battery compartment, and charges 

up to 33 Ah batteries in an external cabinet 

Power Supply Output Details 

(Continued)

:

 

 

Battery and Charger Monitoring

 includes battery 

charger status and low or depleted battery conditions; 

status information provided to the master controller 

includes analog values for: battery voltage, charger 

voltage and current, actual system voltage and current, 

and IDNAC SLC current 

 

Low Battery Voltage Cutout 

is selectable when 

required (required for ULC listing applications) 

 

4 A Output Rating.

 

This includes current for:

 

IDNAC 

controlled

 

notification appliances; IDNet devices; 

module currents; and auxiliary output current (battery 

charging, CPU, and power supply current are not 

subtracted from the 4 A)

 

 

2 A Auxiliary Output

 

(AUX/SNAC) 

can be selected 

either as resettable auxiliary power of 2 A @ 24 VDC, 

or selected to be a simple NAC (SNAC) for sounder 

base power, 4-wire detector power, or door holder 

power 

 

Model*

 

Color 

Description 

Supv. 

Alarm 

4007-9201(BA) Red 

4007ES with a 3 A, Class B, IDNAC SLC for up to 127 addressable notification 
appliances, and 4 A output power supply/battery charger; includes IDNet+ 
communications for 100 addressable points 
Note: Add optional module and other currents separately for battery calculations; base 
panel current does not subtract from the 4 A power available for optional modules and 
external loads 

180 mA 

185 mA 

4007-9202(BA) Platinum 

* Models with (BA) are available assembled in the USA by adding the suffix “BA”. 

 

S4007-0002-6  11/2015

Factory 
Programming 
Options

 

Model  

Description 

4007-8810  Factory Programming (select) 

4007-0831  Custom Labels and Programming (requires 4007-8810) 

Field Installed Optional Modules

 

(refer to diagram on page 8 for module locations)

 

Model  

Description 

Supv. 

Alarm 

4007-9801 

Eight Point Zone/Relay Module

; each point is selectable as an IDC input or Relay output, Class A 

IDCs require 2 points (one out and one return); select up to 4 maximum; current shown is for 8 Class 
B IDCs with 4 in alarm, 

detector current is added separately

 (refer to 4007ES Hybrid data sheet 

S4007-0001 for additional information) 

83 mA 

max 

350 mA 

max 

4007-9802 

25 VDC Regulator Module

; 2 A maximum output; use to power Zone/Relay 

modules connected to initiating devices requiring nominal 25 VDC voltage; refer to 
technical publication 579-832, 

2-Wire Detector Compatibility Chart

 for application 

details 

with 1 module  190 mA 

445 mA 

with 2 modules  290 mA 

801 mA 

with 3 modules  390 mA 

1156 mA

4007-9803 

IDNet+ Loop Expansion Module

; provides an additional isolated loop with short circuit isolation to 

the existing IDNet+ channel, also provides an additional 75 addressable points to the IDNet+ channel 
capacity, maximum of two 

NA NA 

4007-9804 

Dual Class A IDNAC Isolator (DCAI)

; converts a single Class B IDNAC SLC input to two Class A or 

two Class B SLC outputs; provides short circuit isolation between each Class A or B output circuit; 
requires one IDNAC address; the total current remains controlled by the Class B input source SLC at 
3 A maximum 

8.3 mA 

18.5 mA 

4007-9805 

Panel Mounted 48 LED Status Annunciator Module

; provides 24 Yellow LEDs, 

20 Red LEDs, and 4 Red/Green LEDs that are programmable for up to 24 IDC zones of 
alarm and trouble annunciation, or as required for custom annunciation requirements 

no LEDs on 

10 mA 

10 mA 

with  

LEDs on 

1.75 mA per LED, 

105 mA max 

4007-9806 

SDACT Module

 for Point or Event Reporting; order 2080-9047 connection cables as required (see 

cable details under accessories) 

30 mA 

40 mA 

4007-9807 

City Circuit Module

 with Disconnect Switch 

20 mA 

36 mA 

4007-9808 

City Circuit Module

 without Disconnect Switch 

20 mA 

36 mA 

4007-9809 

Relay Module

; relays for Alarm, Supervisory, and Trouble; rated 2 A resistive @ 32 VDC 

15 mA 

37 mA 

continued on next page

 Module and Accessories Selection Information

 

 Power Supply Output and Zone/Relay Module Details

 

 Product Selection

 

Summary of Contents for 4007-9201

Page 1: ...on board memory to allow easy selection of desired revision An internal Ethernet service port and an internal serial service port are available for service computer connections to perform configuratio...

Page 2: ...puter or to the USB drive Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring WALKTEST silent or audible system test performs an...

Page 3: ...in Menu May 27 2015 12 24 PM System Trouble Screen identifies active troubles with custom labels displayed arrows allow navigation through the list Trouble Log Screen allows review of past troubles wi...

Page 4: ...data sheet S4098 0052 for details TrueAlarm heat sensors can be selected for fixed temperature detection with or without rate of rise detection Utility temperature sensing is also available typically...

Page 5: ...area zone covered by appliances on the notification appliance circuit NAC making it much more difficult and costly to locate and correct the source of a problem Using the TrueAlert magnet test allows...

Page 6: ...num Models with BA are available assembled in the USA by adding the suffix BA 6 S4007 0002 6 11 2015 Factory Programming Options Model Description 4007 8810 Factory Programming select 4007 0831 Custom...

Page 7: ...tion Manual 579 1103 4007ES Hybrid Data Sheet S4007 0001 Detailed Operator s Manual 579 1165 Field Installed Optional Modules Model Description Supv Alarm 4190 8001 TrueInsight Remote Service Gateway...

Page 8: ...9803 IDNet Loop Expansion Modules maximum of two two are shown 4 IDNAC Power Supply Assembly 5 Location for additional 4007 9801 Zone Relay Module 6 Location for additional 4007 9801 Zone Relay Module...

Page 9: ...009 IDNet NAC Extender S4009 0002 Battery and Battery Cabinet Reference S2081 0006 4003EC Voice Control Panel S4003 0002 Seismic Battery Brackets Reference S2081 0019 4606 Series Color LCD Touchscreen...

Page 10: ...f Test TrueAlert addressable appliance not TrueAlert ES addressable appliance Note Additional TrueAlert ES Self Test information is detailed in Operating Instructions 579 1165 shipped with the panel S...

Reviews: