Pulse mode (default setting) is switched off and the pulse duration no
longer plays a role. When flip-flop mode is activated, SmartRelay
changes its status from on to off or vice versa each time it is activated
using a transponder. This mode is ideal for switching lights, machines
and other systems on and off.
Where applicable, you should ensure that mains adapters and electric
strikes are suitable for continuous current operation in such an
installation.
Internal antenna always on
Even if an external antenna is connected, the internal antenna is still
used at the same time.
Close range mode (for internal antennas only)
Close range mode is activated.
Time switch-over function
For ZK and ADV only. A time zone plan needs to be uploaded when the
time switch-over is activated. This allows SmartRelay to remain
unlocked during the indicated times (in Group 5). During the day, the
door can be used freely while only a transponder will open the door at
night.
You should ensure that mains adapters and electric strikes are suitable
for continuous current operation in such an installation
Permit exceptions in time zone management
Exceptions are permitted in time zone management if this checkbox is
enabled.
Card interface
This option is enabled for all G2 SmartRelays as standard. The LSM first
adds a data record for an active locking device and checks whether the
locking device has an interface during programming. If no card interface
is detected, LSM automatically disables the checkbox. You no longer
need to indicate whether you have an active or hybrid SmartRelay G2
for LSM 3.3 or higher.
IMPORTANT
If you change the card interface setting manually, automatic detection will
no longer function and warning messages will be emitted.
Some settings can be specified using the "Extended configuration" button:
Interface
SREL1+2
(Manual)
6. Configurations in the software