Quick Start Guide

IED1522LR Logic / Relay Module

AtlasIED.com

TELEPHONE: (800) 876-3333

[email protected]

1601 JACK MCKAY BLVD. 

ENNIS, TEXAS 75119 U.S.A.

Please note that this guide applies to Rev2 of the device, easily distinguished by the AtlasIED logo on the front, rather than the previous version that 
displayed the IED logo in the same area.

Welcome

Thank you for choosing AtlasIED and the IED1522LR Logic / Relay Module. The IED1522LR Logic / Relay Module is a cost effective interface module 
that operates as an integral part of an AtlasIED GLOBALCOM

®

 system. 

It is a web-enabled, programmable relay device for a wide variety of remote control and automation applications. It has two electro-mechanical relays 
and two optically-isolated inputs. The relays can be controlled remotely using actions configured in the GLOBALCOM

®

 GCK Application (Version 14.6 or 

later). The optically-isolated inputs can be used to trigger actions or as logic monitor points that will register faults in the system. 
The module receives its power over IEEE 802.3af PoE and communicates with other system devices over the Ethernet network.

Basic Setup Procedure

Consult the table below to begin the basic setup procedure for the relay module:

In order to prepare the IED1522LR for a GLOBALCOM installation, follow the steps below to set a static IP address:
1.  Connect unit to power and network.
2.  Set up a computer on the same network as the input module. To do this, set the IP address of the computer to 

10.2.150.x

 (where “x” can be any    

  unused address between 1 and 174) with a netmask of 

255.0.0.0

.

3.  Configure the IED1522LR using a web browser. To do this, enter 

http://10.2.150.175/setup.html

. The login username is 

admin

 and the password   

 is 

iednet

 (all lowercase).

4.  Set the permanent IP address, subnet mask, and (optionally) the gateway address in the setup page under the Network tab.
5.  Submit the changes via the 

Submit

 button on the web page.

6.  Reset the IED1522LR via either the 

Reset

 button on the web page or by removing and re-applying power to the unit.

7.  Next, set the computer back to its original or desired network settings for the installation and verify that the IED1522LR can be accessed at its new  
  (permanent) IP address.
8.  Proceed to connect logic inputs and relay outputs as needed for the application.
See the next page for the IED1522LR Pinout Diagram.

Out of Box Default Settings

IP Address

10.2.150.175

Subnet Mask

255.0.0.0

Control Web Address

http://10.2.150.175

Setup Web Address

http://10.2.150.175/setup.html

Setup Username

admin

Setup Password

iednet (all lowercase)

Control Password

No password set