Quick Start Guide
IED1522LR Logic / Relay Module
AtlasIED.com
TELEPHONE: (800) 876-3333
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Please note that this guide applies to Rev2 of the device, easily distinguished by the AtlasIED logo on the front, rather than the previous version that
displayed the IED logo in the same area.
Welcome
Thank you for choosing AtlasIED and the IED1522LR Logic / Relay Module. The IED1522LR Logic / Relay Module is a cost effective interface module
that operates as an integral part of an AtlasIED GLOBALCOM
®
system.
It is a web-enabled, programmable relay device for a wide variety of remote control and automation applications. It has two electro-mechanical relays
and two optically-isolated inputs. The relays can be controlled remotely using actions configured in the GLOBALCOM
®
GCK Application (Version 14.6 or
later). The optically-isolated inputs can be used to trigger actions or as logic monitor points that will register faults in the system.
The module receives its power over IEEE 802.3af PoE and communicates with other system devices over the Ethernet network.
Basic Setup Procedure
Consult the table below to begin the basic setup procedure for the relay module:
In order to prepare the IED1522LR for a GLOBALCOM installation, follow the steps below to set a static IP address:
1. Connect unit to power and network.
2. Set up a computer on the same network as the input module. To do this, set the IP address of the computer to
10.2.150.x
(where “x” can be any
unused address between 1 and 174) with a netmask of
255.0.0.0
.
3. Configure the IED1522LR using a web browser. To do this, enter
http://10.2.150.175/setup.html
. The login username is
admin
and the password
is
iednet
(all lowercase).
4. Set the permanent IP address, subnet mask, and (optionally) the gateway address in the setup page under the Network tab.
5. Submit the changes via the
Submit
button on the web page.
6. Reset the IED1522LR via either the
Reset
button on the web page or by removing and re-applying power to the unit.
7. Next, set the computer back to its original or desired network settings for the installation and verify that the IED1522LR can be accessed at its new
(permanent) IP address.
8. Proceed to connect logic inputs and relay outputs as needed for the application.
See the next page for the IED1522LR Pinout Diagram.
Out of Box Default Settings
IP Address
10.2.150.175
Subnet Mask
255.0.0.0
Control Web Address
http://10.2.150.175
Setup Web Address
http://10.2.150.175/setup.html
Setup Username
admin
Setup Password
iednet (all lowercase)
Control Password
No password set