9 Technical specifications
Radio emissions
SRD
24.45 kHz - 24.47 kHz
-4.7 dBµA/m (10 m dis-
tance)
RFID
13.558 MHz - 13.564
MHz
4.1 dBµA/m (10 m dis-
tance, V=13.2)
SRD (WaveNet) (de-
pending on equipment)
868.000 MHz) -
868.600 MHz
<25 mW ERP
There are no geographical restrictions within the EU.
9.1 Technical specifications for SREL
Housing made of black plastic: di-
mensions l x w x h
72 x 57 x 25.5 mm
Protection rating
IP20, not tested for outside use
Temperature
When operating: -22°C to 55°C
In storage: 0 °C to 40°C
Humidity
< 95% without condensation
Circuit board dimensions l x w x h
50 x 50 x 14 mm
Mains voltage
12 V AC or 5-24 VDC (no reverse
voltage protection)
Power limitation
Mains adapter must be limited to 15
VA
Standby current
< 5 mA
Max. current
< 100 mA
Pulse duration programmable
0.1 to 25.5 seconds
Output relay type
Changeover contact
Output relay continuous current
Max. 1.0 A
Output relay switch-on current
Max. 2.0 A
Output relay switching voltage
Max. 24 V
Output relay switching power
10^6 activations at 30 VA
Multi-function connections F1, F2, F3 Max. 24 V DC, max. 50 mA
Vibrations
15 G for 11 ms,
6 shocks as per IEC 68-2-27
Not approved for use when subject
to permanent vibrations
SREL1+2
(Manual)
9. Technical specifications
32 / 38