114
ENG
In “
advanced
” we can modify the following values:
Depending on the function we want to incorporate, different
tabs open for its configuration.
If we press on the arrows we can configure the same parame-
ters for the detection moment (
Initial Action
) and for the stop
detecting moment (
Final Action
).
Initial or final action
·
Turn on:
On detecting it turns on the channel in question.
·
Turn off:
On detecting it turns off the channel in question.
·
Toggle:
On detecting it changes the channel’s status.
·
Set Value:
For the selected action (Turn on, Turn off or
Toggle), change the setting value of the channel, group or
scenario the sensor controls.
·
Time delay:
For the selected action (Turn on, Turn off or
Toggle), time delay its action.
*For the final action, we must press the right or left arrow and
we will be able to modify the same parameters but for the
detector’s final action.
5.12 CLC Creation
A
CLC
is an analog sensor by means of which we can maintain a constant light level in a zone using external
light, consuming only what is necessary for our requirements.
To create a CLC, we need to have an analog sensor in the installation and to have installed a Scena device
(Digital inputs module).
We need to have registered a channel as analog type
(see page 96).
To add or modify a CLC’s parameters, we must press CLC in
“
System
”.
To add a CLC, press “
add
”.
Summary of Contents for Scena
Page 1: ...MANUAL Y GU A DE INSTALACI N SCENA MANUAL AND INSTALLATION GUIDE...
Page 4: ...4 CAST...
Page 17: ...17 CAST 2 2 6 Modulo Regulador 0 10V 2 2 7 Modulo control de Persianas...
Page 60: ...60 CAST 2 Conexionado tipo...
Page 70: ...70 CAST MANUAL AND INSTALLATION GUIDE...
Page 73: ...73 ENG...
Page 86: ...86 ENG 2 2 6 0 10V Regulator Module 2 2 7 Blind control module...
Page 129: ...129 ENG 2 Standard Connection...