User manual for Digital Indicator and cooperating software
In order to assembly the unit, a 90,5 x 90,5 mm mounting hole (Fig. 4.1) must be
prepared. The thickness of the material of which the panel is made must not exceed
5mm. When preparing the mounting hole take the grooves for catches located on
both sides of the housing into consideration (Fig. 4.1). Place the unit in the
mounting hole inserting it from the front side of the panel, and then fix it using the
brackets (). The minimum distances between assembly holes’ axes - due to the
thermal and mechanical conditions of operation - are 115 mm x 115 mm (Fig. 4.4).
Fig. 4.1. Mounting hole dimensions
Fig. 4.2. Installing of brackets, and dimensions of connectors.
9
90,5 mm
13 mm
8 mm
8 mm
13 mm
1 mm
max. 5 mm
9
0,
5
mm
1 mm
92 mm
5 mm
12 mm
10 mm
8
,5
m
m
16
m
m