User manual - METER SRP-73
11.1.
LIST OF REGISTERS
Register Write
Range
Register description
01h
No
-999 ÷ 9999 Measurement value (no decimal point)
02h
No
0h, A0h, 60h
The status of the current measurement;
0h
- data valid;
A0h
- top
border of the measurement range is exceeded;
60h
- bottom border
of the measurement range is exceeded;
03h
Yes
0 ÷ 3
“
Pnt
” parameter in “
InPt
” menu (decimal point position)
0
- “
0
”;
1
- “
0.0
”;
2
- “
0.00
”;
3
- “
0.000
”
04h
Yes
see descr.
State of the relays and alarm LED (binary format)
(1 - on, 0 - off):
00000000 000e00ba
a
- relay R1;
b
- relay R2;
e
- alarm LED;
If written, only
a
,
b
bits are important (others are ignored) these
bits allows user to control the relays via RS-485 interface
06h
No
-999 ÷ 9999 Peak (drop) value (no decimal point)
10h
Yes
0 ÷ 5
“
tyPE
” parameter in “
InPt
” menu (nominal input range).
0
- 0-20 mA range;
1
- 4-20 mA range;
2
- 0-10 V range;
3
- 2-10 V range;
4
- 0-5 V range;
5
- 1-5 V range
11h
Yes
0 ÷ 5
“
CHAr
” parameter in “
InPt
” menu (characteristic type)
0
- linear ;
1
- square;
2
- square root;
3
- user defined;
4
- volume
characteristics of a cylindrical tank in the vertical position;
5
-
volume characteristics of a cylindrical tank in the horizontal position
12h
Yes
0 ÷ 5
“
FiLt
” parameter in “
InPt
” menu (measurement filtering rate)
13h
Yes
0 ÷ 3
“
Pnt
”parameter in “
InPt
” menu (the copy of 03h register, decimal
point position)
0
- “
0
”;
1
- “
0.0
”;
2
- “
0.00
”;
3
- “
0.000
”
14h
Yes
-999 ÷ 9999 “
Lo C
” parameter in “
InPt
” menu, no decimal point included
15h
Yes
-999 ÷ 9999 “
Hi C
” parameter in “
InPt
” menu, no decimal point included
16h
Yes
0 ÷ 999
“
Lo r
” parameter in “
InPt
” menu, in 0.1%
17h
Yes
0 ÷ 199
“
Hi r
” parameter in “
InPt
” menu, in 0.1%
18h
Yes
0 ÷ 9999
“
t h1
” parameter in “
InPt
” menu, no decimal point included
19h
Yes
0 ÷ 9999
“
t h2
” parameter in “
InPt
” menu, no decimal point included
1Ah
Yes
0 ÷ 9999
“
t h3
” parameter in “
InPt
” menu, no decimal point included
1Bh
Yes
0 ÷ 9999
“
t d
” parameter in “
InPt
” menu, no decimal point included
1Ch
Yes
0 ÷ 9999
“
t Sn
” parameter in “
InPt
” menu, no decimal point included
1Dh
Yes
0 ÷ 9999
“
t Sh
” parameter in “
InPt
” menu, no decimal point included
20h
2
Yes
0 ÷ 199
Device address
21h
No
20F7h
20F3h
Device identification code (ID)
Device identification code (IP65 version)
22h
3
Yes
0 ÷ 7
“bAud”
parameter in
“rS”
menu (baud rate);
0
- 1200 baud;
1
- 2400 baud;
2
- 4800 baud;
3
- 9600 baud;
4
- 19200 baud;
5
- 38400 baud;
6
- 57600 baud;
7
- 115200 baud
45