Installation

3

13. Make certain the power source conforms to the

requirements of your equipment.

14. Protect the electrical cord from sharp objects, hot sur-

faces, oil, and chemicals. Avoid kinking the cord.
Replace or repair damaged or worn cords immediately.

15. Do not touch an operating motor. Motors can oper-

ate at high temperatures.

Risk of electric shock. Shock can burn

or kill. 

If your basement has water or moisture on

floor, do not walk on wet area until all power has
been turned off. If shut-off box is in basement, call
electric company or hydro authority to shut-off ser-
vice to house, or call your local fire department for
instructions. Failure to follow this warning can result
in fatal electrical shock.

Risk of electric shock. Shock can burn

or kill. 

Do not handle pump or pump motor with 

wet hands or when standing on wet or damp surface,
or in water. Always disconnect the pump and float
switch from the electrical power source before doing
any maintenance. 

16. Pump water only with this pump.

INSTALLATION

(See Figure 1, Page 4)

The laundry pump system should be located at the low-
est place possible relative to the area to be drained. 
1. Install the inlet pipe in the opening as shown. Use

Teflon

TM

tape to seal threads. See Figure 2 for typical

installation arrangements.

2. Install the discharge plumbing. When using a rigid

pipe, use plastic pipe. Wrap the thread with Teflon

TM

tape. Screw the pipe into the check valve coupling
hand tight +1 to 1-1/2 turns. Make sure the longer

side of the coupling points downward to cover the
check valve.

NOTICE:

The check valve 

MUST

be installed with

the word TOP facing up.

NOTICE:

Do not use ordinary pipe joint compound

on plastic pipe. Pipe joint compound can attack
plastics.

3. A short length of rubber hose (1-7/8” (47.6 mm) I.D.,

or a quick-disconnect should be attached to the dis-
charge line. This will help when removing the pump
for maintenance. A rubber hose may also dampen
pump noise and vibration.

4. Install the in-line check valve on the pump outlet to

prevent backward flow through the pump when the
pump shuts off.

5. Push the vent pipe into the black vent grommet in

the basin cover. The pipe should not extend into the
basin. Connect the pipe to the sewer vent system.

6. Power Supply: The pump is designed for 115V., 60

Hz., operation and requires a minimum 15 amp
individual branch circuit. Both the pump and the
switch are supplied with 3-wire cord sets with
grounding-type plugs. Insert the float switch piggy-
back plug directly into the outlet and the pump plug
into the opposite end of the switch plug.

Risk of electric shock. Shock can burn

or kill. 

The pump should always be electrically

grounded to a suitable electrical ground such as a
grounded water pipe or a properly grounded metallic
raceway, or ground wire system. Do not cut off
round ground pin.

7. If the pump discharge line is exposed to outside sub-

freezing atmosphere, the portion of line exposed
must be installed so any water remaining in pipe will
drain to the outfall by gravity. Failure to do this can
cause water trapped in discharge line to freeze
which could result in damage to the pump.

8. Install easy disconnecting fittings on the inlet pipe and

on the discharge pipe just below the check valve.

9. After the piping and check valve have been installed,

the unit is ready for operation.

10. Check operation by filling the basin with water and

observing the pump’s operation through one com-
plete cycle.

Risk of Flooding. Flooding may cause

personal injury or property damage.

Failure to make

this operational check may lead to improper opera-
tion, premature failure, and flooding.

TM

E.I. DuPont de Nemours and Company Corporation.

Pump Outlet

Check Valve

1 1/4" Coupling

Check Valve  Installation.

Summary of Contents for 2925B

Page 1: ...468 7867 Fran ais Pages 8 13 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 468 7867 Espa ol Paginas 14 19 2004 PRIN...

Page 2: ...ormally To prevent possi ble water damage due to flooding consult your dealer about installing a high water alarm See the Troubleshooting Chart in this manual for information about common sump pump pr...

Page 3: ...astics 3 A short length of rubber hose 1 7 8 47 6 mm I D or a quick disconnect should be attached to the dis charge line This will help when removing the pump for maintenance A rubber hose may also da...

Page 4: ...should be removed and checked for the cause of the difficulty Low voltage long extension cords a clogged impeller very low head or lift etc could cause cycling Refer to the Troubleshooting Chart on Pa...

Page 5: ...o improper operation premature pump failure and flooding Risk of Electric shock Shock can burn or cause death When servicing the system always discon nect power cord from the electrical outlet To Repl...

Page 6: ...f proper size or run Low line voltage If the voltage is under the recommended minimum check the size of the wiring from the main switch on the property If OK contact power company or hydro authority D...

Page 7: ...67 Repair Parts 7 Key No Description Qty Part No 1 10 Gallon Poly Basin Assembly 1 PS51 1P 2 Automatic Vertical Float Switch 1 PKG 208 3 Check Valve 1 ZB902110 4 3 10 HP Submersible Sump Pump 1 2957 0...

Page 8: ...v d eau Se reporter au tableau Recherche des pannes de cette Notice pour tout renseignement concernant les prob l mes les plus courants des pompes de puisard et comment y rem dier Pour de plus amples...

Page 9: ...m tre int rieur ou un dispositif de branchement rapide doit tre branch sur la conduite de refoulement Ceci per mettra de d poser la pompe pour l entretenir Un tuyau souple en caoutchouc peut galement...

Page 10: ...s d bris Proc der l entretien p riodique selon le besoin Risque d inondation Les inondations risquent de causer des blessures corporelles ou des dommages mat riels Ce sys t me de pompage de buanderie...

Page 11: ...e la mort Pour inter venir sur le syst me toujours d brancher le cordon lectrique de la prise de courant Pour remplacer l interrupteur flotteur NOTA L interrupteur flotteur doit toujours pouvoir se d...

Page 12: ...de calibre ad quat pas ou ne fonctionne Tension de ligne basse Si la tension est inf rieure la tension minimale recommand e pas v rifier le calibre des conducteurs de l interrupteur principal de la pr...

Page 13: ...N de pi ce 1 Bassin en plastique de 38 litres 10 gallons 1 PS51 1P 2 Interrupteur flotteur vertical fonctionnement automatique 1 PKG 208 3 Clapet de non retour 1 ZB902110 4 Pompe de puisard submersibl...

Page 14: ...stalaci n de una alarma de nivel alto de agua Consulte la Lista de localizaci n de Fallas en este manual para obtener informaci n sobre los proble mas comunes con bombas de sumidero y sus soluciones P...

Page 15: ...positi vo de desconexi n r pida en la l nea de descarga Esto ser til cuando se deba retirar la bomba para los trabajos de man tenimiento Una manguera de caucho tambi n puede servir para amortiguar el...

Page 16: ...alice los trabajos de mantenimiento rutinario que se requieran Riesgo de inundaci n Las inundaciones pueden ocasionar lesiones personales o da os materiales Este Sistema de bomba de lavadero viene con...

Page 17: ...n el sistema siempre desconecte el cord n el ctrico del tomacorriente Para cambiar el interruptor de flotador AVISO El flotador debe poder completar todo su ciclo sin interfer encia de ning n otro obj...

Page 18: ...i la tensi n se encuentra por debajo del m nimo recomendado verifique el tama o de los cables desde el interruptor principal en la propiedad Si es correcto comun quese con la empresa de energ a o con...

Page 19: ...n Cant repuesto No 1 Unidad de compartimiento de polietileno de 38 litros 10 galones 1 PS51 1P 2 Interruptor de flotador vertical autom tico 1 PKG 208 3 V lvula de retenci n 1 ZB902110 4 Bomba de sumi...

Page 20: ...ty This warranty shall not apply to acts of God nor shall it apply to products which in the sole judgement of SIMER have been subject to negligence abuse accident misapplication tampering alteration n...

Reviews: