- Open the automatic limit stat cap two or
three turns (11 fig. 3)
- Open the filling cock (2 fig. 5) until the
pressure indicated on the water gauge
reaches 1 bar.
When you have finished filling the system
close the fill cock.
2.6.1
System draining
To drain the system, turn off the boiler and
use the discharge valve (9 fig. 5).
2.7
COAXIAL DUCT
ø 60/100
The air inlet-smoke outlet assembly, code
8096250, is included in the standard sup-
ply of the appliance complete with mounting
instructions.
2.7.1
Coaxial duct
accessories
The accessories to be used for this type of
installation and some of the connecting
systems that may be adopted are illustred
in fig. 6.
With the pipe bend included in the kit, the
maximum length of the piping should not
exceed 4.6 meter.
When
the
vertical
extension
code
8086950 is used, the terminal part of the
pipe must always come out horizontally.
2.7.2
Coaxial duct outlet
on the roof
The accessories to be used for this type of
installation and some of the connecting
systems that may be adopted are illustra-
73
IT
ES
PT
GB
RUS
8
5
7 6
4
2
3
1
9
Fig. 5
KEY
1 D.H.W. inlet-outlet manifold
2 Filling cock
3 D.H.W. filter
4 Manifold by-pass
5 Water rate adjuster
6 D.H.W. exchanger
7 Microswitches
8 Flowmeter
9 Boiler discharge
Fig. 6
KEY
1a-b Coaxial duct kit code 8096250
2a
Extension L. 1000 code 8096150
2b
Extension L. 500 code 8096151
3
Vertical extension L. 140 with take-off point code 8086950
4a
90° additional bend code 8095850
4b
45° additional bend code 8095950
IMPORTANT:
Each additional 90° curve installed
reduces the available length by 0.90
metres.
Each additional 45° curve installed
reduces the available length by 0.45
metres.
max 4,6 m
NOTE
Before connecting accessories, it is always advisable to
lubricate the internal part of the gaskets with silicon
products. Avoid using oils and greases.
Summary of Contents for FORMAT DEWY.zip 25 BF
Page 1: ...Format Dewy zip IT ES PT GB CERTIFICAZIONE DEL SISTEMA DI QUALITA AZIENDALE RUS ...
Page 113: ......
Page 114: ......
Page 115: ......