34
1.1
INTRODUCTION
The new ESTELLE HE ErP series of cast
iron boilers condensing they use light oil
and have a perfectly balanced combus-
tion with a very high thermal efficiency
for economical performance.
1 BOILER DESCRIPTION
1.2
DI MEN SIO NAL DETAILS (fig. 1)
460
=
=
277
850
Ø 130
A
D
95
=
=
M
R
S
P
505
B
C
Fig. 1
MODEL
SERIAL NUMBER
YEAR OF CONSTRUCTION
WATER CONTENT IN BOILER
HEAT INPUT MAX
HEAT OUTPUT MAX
MAX OPERATING PRESSURE
CONTENTS D.H.W.
HEAT INPUT MAX D.H.W.
MAX OPERATING PRESSURE D.H.W.
D.H.W. FLOW RATE
POWER SUPPLY
MAX POWER ABSORBED
TYPE
CODE
DIRECTIVE OF REFERENCE
PIN NUMBER
MAX OPERATING PRESSURE
MAX OPERATING PRESSURE D.H.W.
1.2.1 Technical data plate (fig. 1/a)
Fig. 1/a
Estelle HE
3 ErP
4 ErP
5 ErP
6 ErP
7 ErP
P Depth (mm)
795
895
995
1095
1195
A mm
330
330
325
325
325
B mm
28
28
128
128
128
C mm
28
28
33
33
33
D mm
330
330
390
390
390
M C.H. flow
G 1” (UNI-ISO 228/1)
G 1” (UNI-ISO 228/1)
G 1” (UNI-ISO 7/1)
G 1” (UNI-ISO 7/1)
G 1” (UNI-ISO 7/1)
R C.H. return
G 1” (UNI-ISO 228/1)
G 1” (UNI-ISO 228/1)
G 1” (UNI-ISO 7/1)
G 1” (UNI-ISO 7/1)
G 1” (UNI-ISO 7/1)
S
Boiler drain
Rp 1/2” (UNI-ISO 228/1) Rp 1/2” (UNI-ISO 228/1) Rp 1/2” (UNI-ISO 228/1) Rp 1/2” (UNI-ISO 228/1) Rp 1/2” (UNI-ISO 228/1)