TO TURN ON THE HEATING

– Turn on the main switch.

– Set the correct hour of the day and the day of the week.

– Place in automatic mode with the button

.

TO SET THE HOUR

HOW TO USE THE AUTOMATIC MODE

In the automatic mode the temperature of the room is regu-

lated on the basis of the periods of heating chosen.

– Push the button

.

NOTE: Select the heating periods according to one’s daily

requirements;  in  this  way    it  is  possible  to  significantly

save on energy.

TO ACTIVATE CONTINUOUS HEATING

The continuous heating mode keeps the temperature of the

room at the set level via the regulating knob.

– Push the “Continuous Operation” button

.

– Regulate the room temperature with the 

regulating knob.

TO SET THE STANDBY MODE

(when the user is away for a long period of time)

The  standby  mode  keeps  the  temperature  of  the  room  at

the level of antifreeze protection.

– Push the “Standby mode” button

.

MEANING OF THE SYMBOLS

On the display a few of the symbols indicate the current ope-

rating  state.  The  appearance  of  a  line  under  one  of  these

symbols  signals  that  the  corresponding  operating  state  is

“active”.

Heating at the nominal temperature 

(regulating knob)

Heating at reduced temperature (line

).

Heating at antifrost protection temperature 

(line

).

NOTE:  For  further  information  on  the  symbols  and  the

operating  state  refer  to  the  detailed  description  of  the

heating plant.

TO VARY THE HOT WATER PRODUCTION

The production of hot water can be activated or deactivated

by the push of a button.

– Push the button “Hot water”

.

IF THE HOT WATER IS TOO HOT OR TOO COLD

IF THE ROOMS ARE TOO HOT OR TOO COLD

– Check that current operating state on the display.

– In the case of 

nominal temperature

.

Increase or reduce the temperature of the room with the

regulating knob.

– In the case of 

reduced temperature

.

NOTE: After each regulation wait at least two hours for

the new temperature to expand through the room.

TO CHANGE THE HEATING PERIODS

With reference to the day chosen set the changes

as following:

NOTE:  The  heating  periods  automatically  repeat  on  a

weekly basis. 

To this end select the automatic mode.

It is possible to reset the standard programme on line 23

by pushing the b and – at the same time.

IF THE HEATING DOES NOT WORK PROPERLY

– Refer to the detailed documentation 

on the heating system, following the fault finding 

instructions.

TO MEASURE GAS COMBUSTION

– Push the “chimneysweep” button 

.

The heating will work according to the level requested.

HOW TO SAVE ENERGY WITHOUT FOREGOING ON COMFORT

– A  temperature  of  around  21°C  is  advised  in  the  rooms

that are used. Every degree above this will increase hea-

ting costs by 6–7%.

– Aerate the rooms only for a brief period, opening the win-

dows completely.

– In the rooms that are not used place the regulating valve

in the antifreeze position.

– Leave  the  space  in  front  of  the  radiators  free  from

obstructions (remove furniture, curtains...).

– Close windows and blinds to reduce 

dispersion of heat.

Select the

Display

Set the regulation

line

with the buttons

hour of the day

day of the week

1

2

14

15

Select the

Display

Pre-select the weekly block

line

or the single day

1-7 = week
1 = Lu/7 = Do

5

Period

Push

Display

Set

For

requested

button

hour

°C

Start

End

Start

End

Start

End

6

7

8

9

10

11

Select the

Display

Change the temperature

line

with the buttons

°C

14

P

e

riod 

1

P

e

riod 

2

P

e

riod 

3

13

Select the

Display

Set the desired

line

temperature

°C

36

IT

GB

FR

BE

DE

CONTROL SYSTEM

In order to get the highest potential out of the 

“RVA 43.222”

regulator follow the instructions given below:

Summary of Contents for EKO 3 OF

Page 1: ...he discharge channel of the combustion waste is free Check that gate valves are open if there are any Check that the heating system has been filled with water and that air has been bled out of it Make sure that the circulator is not blocked Purge the system bleeding off the air present in the gas pipe by operating the pressure relief valve on the gas valve inlet FONDERIE SIME Co Ltd based in Garbo...

Page 2: ...E BOILER 1 2 DIMENSIONS 1 2 1 EKO 3 6 OF 3 4 OF PVA version CONNECTIONS M Delivery to heating system R 1 UNI ISO 7 1 M1 Delivery to heating system PVA ver R 1 UNI ISO 7 1 G Gas supplier R 3 4 UNI ISO 7 1 R Return to heating system R 1 UNI ISO 7 1 S Boiler discharge pipe Rp 1 2 UNI ISO 7 1 C1 Boiler loading vers PVA Rp 1 2 UNI ISO 7 1 L P K ø D 3 0F 460 675 110 3 OF PVA 460 675 60 110 4 0F 560 675 ...

Page 3: ...t 16 5 mbar and when downstream at 11 5 mbar 6 Intermittent pilot 7 Combustion chamber door 8 Burner manifold 9 Pressure intake 10 Pump EKO 7 OF EKO 8 12 OF KEY 1 Gas valve 2 Probe measurement sheath 3 Control Panel 4 Gas pressure switch with minimum rates of pressure in the system calibrated for G20 in ascent at 16 5 mbar and in descent at 11 5 mbar 6 Intermittent pilot 7 Combustion chamber door ...

Page 4: ...312BP4117 1312BP4117 Category II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P Type B11BS B11BS B11BS B11BS B11BS B11BS Maximum operating pressure bar 4 4 4 4 4 4 Maximum operating temperature C 85 85 85 85 85 85 Water contained in Boiler l 14 18 17 22 20 23 Boiler s cast iron elements n 3 3 4 4 5 6 Temperature regulation C 40 85 40 85 40 85 40 85 40 85 40 85 Expansion tank Capacity pressure preloading l...

Page 5: ...8 1312BP4118 1312BP4118 1312BP4118 Category II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P Type B11 B11 B11 B11 B11 B11 Maximum operating pressure bar 4 4 4 4 4 4 Maximum operating temperature C 85 85 85 85 85 85 Water contained boiler l 26 29 32 35 38 41 Boiler s cast iron elements n 7 8 9 10 11 12 Temperature regulation C 40 85 40 85 40 85 40 85 40 85 40 85 Principle Gas Nozzles Quantity of Nozzles n...

Page 6: ...ed 20 C For this reason it is advisable to install a mixer valve CAUTION The system circulation pump or pumps must go into action at the time of boiler ignition For this reason you are recommended to use an auto matic system of precedence The gas connection must be made using seamless steel pipe Mannesmann type which is galvanized and has threaded joints provided with gaskets excluding three piece...

Page 7: ...ust be rounded off with a radium of no less than 20 mm hydraulically equivalent sections are also permitted fitted with a chimney at the top the outlet of which must be outside the so called reflux area to prevent for mation of counter pressure preven ting the products of combustion from being freely released into the environ ment It is thus necessary to comply with the minimum heights shown in fi...

Page 8: ...tallation of an optional control unit RVA 43 222 cod 8096303 marked with different colours black orange and brown fig 5 Connectors are polarised so that the order cannot be inverted To install the control unit connect these connectors and remove jumpers 13 14 and 15 17 marked with bold letters in the electric system of the figure 6 from the terminal board The control unit also permits the use of r...

Page 9: ...E Type QAC31 outdoor temperature probe optional SC Type QAZ21 boiler immersion probe optional SS Type QAZ21 boiler immersion probe optional PI Heating system pump vers 3 4 OF PVA PB Boiler pump C Connectors of the control unit black orange brown F Fuse T 200 mA TI Insulation transformer only for FR BE PBY Recirculation pump TM Minimum temperature thermostat Only for vers 3 4 OF PVA NOTE During the...

Page 10: ...lation Boiler temperature is controlled on the basis of climate permitting envi ronmental compensation There is direct heating circuit mana gement with pump for each control ler Automatic adaptation to a climatic curve on the basis of the building s thermal inertia and the presence of free heat sources with environmen tal compensation On off optimisation accelerated hea ting and early off feature ...

Page 11: ...en though the pilot bur ner is lit After 60 seconds have ela psed the sparks cease the burner goes out and the warning lamp indica ting equipment lock out lights up This occurs when the positions of live and neutral have not been respected on the terminal block There is a break in the wire of the sensing electrode or the electrode itself is earthed the electrode is worn out and needs repla cing Th...

Page 12: ... the working pressures have been adjusted reseal the regulators When the gas pressures are to be reset this must be done following a set order first the maximum pressure and then the minimum 4 INSTRUCTIONS FOR USE AND MAINTENANCE 9 1 4 3 7 8 2 KEY 1 Coil EV1 2 Pressure regulator 3 Coil assembly 4 Coil EV2 7 Pressure inlet upstream 8 Pressure inlet downstream 9 Gas pressure switch of minimum rate a...

Page 13: ...n upstream at 27 mbar and when downstream at 22 mbar In the models with a gas valve VRB 25PA instead turn the knob of the mini mum rate pressure 9 fig 9 chan ging the rate from 11 5 mbar for G20 to 22 mbar for G31 In order to regulate the power heat fol low the instructions of 4 1 Once the operating pressures have been changed seal the regulators Apply the plate provided in the kit for identificat...

Page 14: ...ich covers a rate from 40 to 85 oC The temperature that has been fixed can be controlled on the thermometer SAFETY THERMOSTAT fig 16 The safety thermostat is of the manually resetting type and turns on IGNITION AND FUNCTIONING 0 120 20 100 40 80 6 C Fig 14 Fig 15 0 120 20 100 40 80 6 C USER S INSTRUCTIONS WARNINGS In case of fault and or incorrect equipment operation deactivate the boiler without ...

Page 15: ...y Should the boiler continue to lock out it will be necessary to make a careful check of the flue pipe making all the necessary modifications and amendments so that it can work properly LOCK OUT RESET OF THE CONTROL BOX fig 18 If the burner fails to ignite the red led on the reset button will turn on Press the button to restart the boiler automatically fig 18 Should the boiler lock out again you m...

Page 16: ...emperature Increase or reduce the temperature of the room with the regulating knob In the case of reduced temperature NOTE After each regulation wait at least two hours for the new temperature to expand through the room TO CHANGE THE HEATING PERIODS With reference to the day chosen set the changes as following NOTE The heating periods automatically repeat on a weekly basis To this end select the a...