67
1.3
TECHNICAL FEATURES
SOLO 20 OF
SOLO 30 OF/BF
SOLO 40-PR 40 OF/BF
Heat output minimum-maximum*
kW
18.9-23.5 (20.7)
24.5-31.3 (27.5)
32.5-40.0 (35.2)
kcal/h
16,300-20,200
21,100-26,900
28,000-34,400
kcal/h
(17,800)
(23,700)
(30,300)
Heat input minimum-maximum*
kW
21.1-26.2 (23.0)
27.2-34.8 (30.6)
36.0-44.3 (39.0)
kcal/h
18,100-22,500
23,400-29,900
31,000-38,100
kcal/h
(19,800)
(26,300)
(33,500)
Type
B
23
B
23
B
23
Elements
n°
3
4
5
Maximum water head
bar
4
4
4
Water content
l
18
22
26
Expansion vessel
Water content/Preloading pressure l/bar
10/1
10/1
10/1
Loss of head smoke
Minimum-Maximum
mbar 0.05-0.11
0.12-0.16
0.15-0.21
Combustion chamber pressure **
mbar
– 0.02
– 0.02
– 0.05
Suggested chimney depression **
Minimum-Maximum
mbar
0.07-0.13
0.14-0.18
0.17-0.23
Smoke temperature minimum-max.
°C
160-185
160-185
160-185
Smoke flow minimum-max.*
m
3
n/h
24.0-31.6 (26.4)
32.4-41.4 (35.9)
42.9-52.8 (46.3)
CO
2
%
12.5
12.5
12.5
Maximum temperature
°C
95
95
95
Power consumption “OF/BF”
W
220
200/230
180-235/210
Adjustment range heating
°C
45÷85
45÷85
45÷85
D.H.W. production
D.H.W. flow rate EN 625
l/min
–
–
–
Contin. D.H.W. flow rate
∆
t 30°C
l/h
–
–
–
Minimum D.H.W. flow rate
l/min
–
–
–
D.H.W. tank maximum water head
bar
–
–
–
Gas-oil burner ***
Burner nozzle *
0.50-0.60 60°W
0.60-0.75 60°W
0.75-0.85 60°W
(0,50 60°W)
(0.65 60°W)
(0.85 60°W)
Pump pressure min.-max. *
bar
12-12 (14)
14-14 (14)
14-14 (12)
Shutter position min.-max. for
“OF”
vers.*
3.2-3.7 (3.4)
3.0-5.2 (4.1)
5.0-6.2 (5.3)
Shutter position min.-max. for
“BF”
vers.*:
coaxial exhaust ø 80/125
–
1.7-4.1 (4.0)
1.8-3.6 (2.4)
separate flues ø 80
–
1,0-2,0
–
Diaphragm position for
“BF”
vers.*:
coaxial exhaust ø 80/125
–
D-G (D)
–
separate flues ø 80
–
M
–
Weight
kg
112
137
162
*
The date shown between the brackets refer to the factory settings
** For
“OF”
versions only
*** After changing the calibration values of the burner, always check the C0
2
values.