40
7.4
List of parameters
Type
No.
Description
Range
U/M
Step
Default
CONFIGURATION
PAR
01
Index showing boiler power in kW
2 = 30 kW (G20)
4 = 40 kW (G20)
8 = 30 kW (G31)
10 = 40 kW (G31)
-
1
2; 4 ; 8
; 10
PAR
02
Hydraulic configuration
0 = rapid
1 = storage tank with thermostat or
heating only
2 = hot water tank with sensor
3 = bithermic
4=instant with solar power input
5 = open vent
6 = boiler with heat pump
9 = „Hybrid Wall“
10 = Hybrid Wall “T” hot water tank
boiler
-
1
0
PAR
07
Thermal gradient for Hybrid Wall defrosting aid
0 .. 30
°C/min
1
10
PAR
08
External sensor value correction
-5 .. +5
°C
1
0
PAR
09
Ignition fan speed
80 .. 160
RPMx25
1
128
DOMESTIC HOT WATER - HEATING
PAR
10
Boiler Antifreeze Threshold
0 .. +10
°C
1
3
PAR
11
External Sensor Antifreeze Threshold
-- = Disabled
-9 .. +5
°C
1
-2
PAR
12
Heating Curve Incline
0 .. 80
-
1
20
PAR
13
Minimum Heating Temperature Adjustment
20 .. PAR 14
°C
1
20
PAR
14
Maximum Heating Temperature Adjustment
PAR 13 .. 80
°C
1
80
PAR
15
Maximum power heating
0 .. 100
%
1
100
PAR
16
Heating Post-Circulation Time
0 .. 99
seconds
x 10
1
3
PAR
17
Heating Pump Activation Delay
0 .. 60
seconds
x 10
1
0
PAR
18
Heating Re-ignition Delay
0 .. 60
Min
1
3
PAR
19
Domestic Hot Water Modulation with Flow meter
0 = Disabled
1 = Enabled
-
1
1
PAR
20
Maximum power domestic hot water
0 .. 100
%
1
100
PAR
21
Minimum power heating/domestic hot water
(premixed)
0 .. 100
%
1
0
PAR
22
Domestic hot water preheating enabling
0 = OFF
1 = ON
-
1
0
PAR
23
External relay 1 function
0 = not used
1 = remote alarm NO
2 = remote alarm NC
3 = zone valve
4 = automatic filling
5 = external request
6 = recirculation pump
7 = zone valve with OT
8 = relaunch pump
9 = boiler with heat pump
(circulator)
-
-
0
PAR
24
External relay 2 function
0 = not used
1 = remote alarm NO
2 = remote alarm NC
3 = zone valve
4 = automatic filling
5 = external request
6 = recirculation pump
7 = zone valve with OT
8 = relaunch pump
9 = boiler with heat pump
(circulator)
13 = management of the heat
pump for Hybrid Wall
-
-
0
Summary of Contents for 8116902
Page 4: ...4 ...
Page 14: ...14 ...
Page 52: ...52 9 EXPLODED VIEWS Frame ...
Page 53: ...53 Hydraulic assembly ...
Page 54: ...54 Exchanger Combustion ...
Page 55: ...55 Control panel ...
Page 56: ...56 Gas valve Oversleeve Fan ...
Page 77: ...77 ...
Page 78: ...78 ...
Page 79: ...79 ...