RANGE RATED CERTIFICATION
The maximum power, in heating mode, of
Edea
boilers can
be adapted, during the installation, to the thermal needs of
the system by modifying the setting of PAR 15 in the
0 .. 100
range.
The setting of PAR 15 = 100 is the factory setting that allows
the boiler to deliver its maximum power in heating mode. It
can be reduced by modifying the setting of PAR 15 as shown
in the table appearing below.
Once the new setting of PAR 15 has been made, the reduced
maximum power value (kW)
for models with power above 35
kW
MUST MANDATORILY be applied beside the boiler’s data
plate. For checks and adjustments after the modification,
refer to the new value for the maximum power.
The useful nominal power levels used are those relative to the
operating conditions (80-60°C) (Pn min - Pn max).
Example for
Edea 30
:
– default heating power range: 2,8 - 24,5 setting of PAR 15 = 100
– “reduced” heating power range: 2,8 - 18,9 setting PAR 15 = 80
DESCRIPTION
Edea
30
40
Setting of PAR 15
Min
Max
Min
Max
A - Factory power range (heating)
kW
2,8
24,5
4,2
34,1
100
B - Reduced power ranges for
maximum power reduction
(heating)
kW
2,8
21,2
4,2
30,7
90
kW
2,8
18,9
4,2
27,3
80
kW
2,8
16,5
4,2
23,9
70
kW
2,8
14,2
4,2
20,5
60
kW
2,8
11,8
4,2
17,0
50
kW
2,8
9,4
4,2
13,6
40
Boiler technical data plate
Summary of Contents for 8116902
Page 4: ...4 ...
Page 14: ...14 ...
Page 52: ...52 9 EXPLODED VIEWS Frame ...
Page 53: ...53 Hydraulic assembly ...
Page 54: ...54 Exchanger Combustion ...
Page 55: ...55 Control panel ...
Page 56: ...56 Gas valve Oversleeve Fan ...
Page 77: ...77 ...
Page 78: ...78 ...
Page 79: ...79 ...