34
6.12.7 Separate ducts (Ø 80mm) with duct kit C(10)3
The
Edea
boiler is configured for use with type C(10)3 dis-
charge ducts. To ensure correct boiler operation, certain pa-
rameters should be modified in relation to the power and type
of fuel used to power the device.
Set the parameters as specified in the table.
Type
No.
Description
Setting for
Edea
30
METHANE
LPG
PAR
09
Ignition revolutions
-
110
PAR
21
CH/DHW minimum power
15
10
Duct kit C(10)3 code
6296543
6296543
Type
No.
Description
Setting for
Edea
40
METHANE
LPG
PAR
09
Ignition revolutions
-
118
PAR
21
CH/DHW minimum power
9
11
Duct kit C(10)3 code
6296543
6296543
NOTE:
To modify the parameters in the table, proceed as spec-
ified in the paragraph "Parameter setting and display".
The duct kit C(10)3 (1) can be installed both vertically A) and
horizontally (B).
1
Ø80
A
Fig. 29
If it is installed horizontally, when positioning the internal but-
terfly valve make sure that its fins (2) face upwards, so that
they remain closed by effect of their weight. Moreover, it is
necessary to remove the siphon (3) and mount the cap (4) sup-
plied with the kit.
3
B
2
4
Fig. 30
6.13 Electrical connections
The power cable must be connected to a 230V (±10%) ~ 50 Hz
network, observing L-N polarity and the earth connection. The
network must have an omnipolar switch with category III over-
voltage, in compliance with the installation rules.
If this cable needs to be replaced, an original spare must be
requested from
Sime Ltd
.
Therefore only the connections of the original components as
shown in the table are needed. These are to be ordered sepa-
rately from the boiler.
DESCRIPTION
CODE
External sensor kit (ß=3435, NTC 10KOhm at
25°C)
8094101
Power cable (dedicated)
6323875
Remote control HOME (open therm)
8092280
Remote control HOME PLUS (open therm)
8092281
m
CAUTION
The maintenance interventions described must
ONLY be carried out the professionally qualified per-
sonnel.
a
WARNING
Before carrying out any interventions described:
– set the main system switch to "OFF"
– close the gas valve
– make sure that no hot parts inside the appliance
are touched.
Summary of Contents for 8116902
Page 4: ...4 ...
Page 14: ...14 ...
Page 52: ...52 9 EXPLODED VIEWS Frame ...
Page 53: ...53 Hydraulic assembly ...
Page 54: ...54 Exchanger Combustion ...
Page 55: ...55 Control panel ...
Page 56: ...56 Gas valve Oversleeve Fan ...
Page 77: ...77 ...
Page 78: ...78 ...
Page 79: ...79 ...