![Sime 8115020 User, Installation And Servicing Instructions Download Page 54](http://html.mh-extra.com/html/sime/8115020/8115020_user-installation-and-servicing-instructions_1274892054.webp)
54
EN
DESCRIPTION
Vera HE
25
30
NOZZLES - GAS
Number of nozzles
No.
1
Nozzle diameter (G20/G31)
mm
5,3
Gas consumption at Max/Min flow rate (G20)
m
3
/h
2,53 / 0,42
3,17 / 0,5
Gas consumption at Max/Min flow rate (G31)
kg/h
1,86 / 0,35
2,32 / 0,37
Gas supply pressure (G20/G31)
mbar
20 / 37
kPa
2 / 3,7
TEMPERATURE - PRESSURE
Max operating temperature (T max)
°C
85
Heating adjustment range
°C
20÷80
Domestic hot water adjustment range
°C
10÷60
Max operating pressure (PMS)
bar
3
kPa
300
Water content in boiler
l
5,10
Lower Heat Output (Hi)
G20 Hi.
9.45 kW/m
3
(15°C, 1013 mbar) - G31 Hi. 12.87 kW/kg (15°C, 1013 mbar)
5.6
Main water circuit
3
4
5
14
13
15
16
18
19
10
9
7
11
17
21
20
12
6
M
U
G
E
R
Sc
S
8
2
1
Fig. 13
KEY:
M System delivery
R System return
U Domestic hot water outlet
E Domesti hot water inlet
S Safety valve outlet
G Gas supply
Sc Condensate outlet
1
Condensing heat exchanger
2
Combustion chamber
3
Fan
4
Thermal safety thermostat
5
Delivery sensor
6
Domestic hot water heat exchanger
7
Pressure transducer
8
Pressure gauge
9
Automatic bleed valve
10
Pump
11
System expansion vessel
12
Diverter valve
13
Automatic by-pass
14
Domestic hot water sensor
15
Gas valve
16
Domestic hot water flow meter
17
Domestic hot water filter
18
Boiler drain
19
System relief valve
20
System filling
21
Condensate siphon outlet