1 DESCRIPTION OF THE APPLIANCE
1.1
Characteristics
Brava Slim HE 25 T ErP
are last generation condensing wall
mounted boilers which
Sime
has produced for heating and
domestic hot water production when combined with a storage
tank. The main design choices made by
Sime
for the
Brava Slim
HE 25 T ErP
boilers are:
– the total pre-mix microflame burner combined with a steel
heat exchanger for heating
– the sealed combustion chamber which can be classified
"Type C" or "Type B" in relation to the room where the boiler
is installed, depending on the smoke outlet configuration
adopted during installation
– the command and control microprocessor electronic board
provides efficient management of both heating and hot water
production. It can also be connected to a remote control
with an Open Therm protocol or to room thermostat and/or
external sensor. If connected to an external sensor, the boiler
temperature varies on the basis of the external temperature
according to a selected optimal climatic curve providing
significant energy and economic savings.
Other special features of the
Brava Slim HE 25 T ErP
boilers are:
– the anti-freeze function which activates automatically if the
temperature of the water inside the boiler falls below the
threshold of the value set at parameter "PAR 10" and , if there
is an external sensor, if the external temperature falls below
the threshold of the value set at parameter "PAR 11"
– the anti-blocking function of the pump and diverter valve, this
activates automatically every 24 hours if no request for heat
has been made
– the chimney sweep function lasts 15 minutes and makes the
job of the qualified technician easier when measuring the
parameters and combustion efficiency
– screen display of the operating and self-diagnostic
parameters with error code display when the fault occurs.
This makes repair interventions easier and allows appliance
operation to be restored correctly.
1.2
Check and safety devices
The
Brava Slim HE 25 T ErP
boilers are equipped with the
following check and safety devices:
– thermal safety thermostat 100°C
– 3 bar relief valve
– heating water pressure transducer
– delivery sensor
– hot water tank sensor
– smoke flue gas probe.
d
IT IS FORBIDDEN
to commission the appliance with safety devices which
do not work or which have been tampered with.
a
WARNING
Safety device may only be replaced by professional
qualified personnel using
Sime
original spare parts.
1.3
Identification
The
Brava Slim HE 25 T ErP
boilers can be identified by means of:
1 Packaging label:
this is located on the outside of the
packaging and provides a code, the serial number of the
boiler and the bar code
2 Energy Efficiency Label:
this is positioned on the outside
of the packaging to notify the User of the level of energy
savings and reduced environmental pollution produced by
the appliance
3 Technical Data Plate:
this is located inside the front panel
of the boiler and provides the technical data, appliance
performance information and any other information required
by law in the country where the appliance will be used.
1
3
1
I II
A
B
C
D
E
F
G
2015
811/2013
Cod. 6244745
dB
kW
A
++
A
+
A
B
C
D
E
F
G
2
3
2
Fig. 1