_UM_9752060610_NL_D_GB_F_V2_0 37
GB
- Route the high-voltage cable to the power unit. See also the power unit user manual.
- Select an external motor safety switch in conformance with IEC60947-2 that is suitable for
the environment in which it is installed. Install it in an easily accessible place.
- Lay the power cable so that it cannot be mechanically loaded and connect it to the mains
connection point via the motor safety switch.
- The motor is supplied as standard to be connected in star at 400 V (3 x 230 V). For use with
a lower voltage, the configuration of the motor terminal box must be changed from star to
delta as shown in figure 3.
- Set the motor safety switch to the rated current as indicated on the motor type plate
(connected in
Ү
as standard ex-works).
Y-switching (high voltage)
∆
-switching (low voltage)
Figure 3: Mains cable connection of motor terminal box
Figure 4: VolumION wiring diagram
BROWN (GREY)
BLACK
GREY (BROWN)
YELLOW/GREEN