The CX-LINK system consists of two units (DigiOptic™ Image
Processor and Projector) of which the former is also the system
control centre.
The system can be controlled from either the remote control
(via the infrared sensors on the DigiOptic™ Image Processor
and on the Projector) or the keypad located on the back of
the Projector.
However, the power supply to the two units is separate.
After interconnecting the units via the fibre optic cable, connect
them to the electrical mains supply:
1) Set the Projector power switch on the rear panel onto “I” (ON)
(Fig.1 phase A).
) Set the DigiOpticTM Image Processor switch on the external
power supply unit to “I” (ON) (Fig. 1 phase B). In this phase
make sure the DigiOptic Image Processor (Fig. 1 phase
C) is in the OFF position: in this condition the indicator LEDs
on the front panel of the DigiOptic Image Processor should
not be lit.
The power-up sequence described at points 1 and must
be observed in full; otherwise the system will not initialise
properly and the power-up sequence must be repeated in
accordance with the proper procedure.
) Press the central button on the front of the DigiOptic™ Image
Processor onto ON (Fig.1 phase C).
After a few seconds (system initialisation interval), the DigiOp-
tic™ Image Processor and the Projector assume stand-by
mode.
System status information is provided by two LEDs (green and
blue) on the front panel of the DigiOptic™ Image Processor
and on the rear of the Projector.
Significant status signals are given in Table .
If the “No optical link” or “Error” signals are active the system
cannot be operated; if the “Warning” signal is active the
system will operate but it may be unable to read certain
input signals correctly.
4) Switching on the system (Fig.14):
• with the remote control ( keys)
• with the Projector keypad ( key)
Off
Initialisation
Status
DigiOptic™ Image
Processor
Projector
Led green Led blue Led blue Led red
SIM2
RED
BLUE
RED
BLUE-OFF
BLUE
RED-BLINK
RED
RED
BLU
Standby
On
Cooling
Link error
Controller error
Fan failure
Overtemperature
Init error (Warning)
: Off
: On
: Blinking
-
-
-
8 SWITCHING ON AND OFF
O
I
O
I
IMAG
E P RO
CESSO
R
OFF
ON
DIGIO
P TIC
™ IMA
GE P
ROCE
SSOR
OFF
ON
A
B
C
~ AC
IN
FUSE
T 5A
H 2
50V~
CLA
SS 1
LAS
ER P
ROD
UCT
ESC
MEN
U
SOU
RCE
CAU
TIO
N: fo
r co
ntinu
ed
prot
ectio
n ag
ains
t risk
of
fire, r
eplac
e onl
y wit
h s
ame
type
and
ratin
g fu
se.
ATTE
NT
ION:
pou
r ne p
as co
mpro
mett
re la p
rotec
tion c
ontre
les r
esqu
es
d’incnd
ie rem
place
r par u
n fu
sible
de m
em
e typ
e et d
e m
ems c
aract
eristiq
ue.
A TEX
AS IN
STRU
MEN
TS TE
CHN
OLO
GY
1
2
3
-
0
I
~ A
C IN
FUSE
T 5A H 250V~
ESC
SOUR
CE
rotec
tion c
ontr
e les r
esq
ues
typ
e et de mems c
arac
teristique
.
0
I
FUSE
T 5A
H 250V
~
CLASS 1 L
ASER PR
ODUCT
ESC
MENU
SOUR
CE
CAU
TION
: for c
ontin
ued
prote
ction
again
st risk
of
fire, r
eplac
e on
ly w
ith sa
me ty
pe an
d rati
ng fu
se.
ATTENTION:
pour ne pas c
ompr
ome
ttre la pr
otec
tion c
ontr
e les r
esques
d’incndie r
emplac
er par un fusibl
e de meme
typ
e et de mems c
arac
teristi
que
.
A TEX
AS IN
STRU
MEN
TS TE
CHN
OLO
GY
1
2
3
-
0
I
RC
I 2005
LIG
HT
??
D
Fig.14
Fig.13
Table 3
SWIT
CHING ON AND OFF